Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1002596.1
Update Date:2010-07-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1002596.1 :   Sun Fire[TM] V1280 - "prtdiag" might not show environmental output for a new System Board  


Related Items
  • Sun Fire V1280 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  

PreviouslyPublishedAs
203589


Symptoms
When a CPU/memory board is newly installed, the system may not show correct SB and environment information (eg. Temperature/Fan data) in "prtdiag" output correctly.

In this example situation below, SB4 is newly installed into a Sun Fire[TM] V1280 system after a normal boot.  The following is the prtdiag output.

% prtdiag -v
System Configuration: Sun Microsystems  sun4u Sun Fire V1280
System clock frequency: 150 MHZ
Memory size: 24GB
CPUs

E$ CPU CPU Temperature Fan CPU Freq Size Impl. Mask Die Ambient Speed Unit
--- -------- ---------- ------ ---- -------- -------- ----- ----
SB0/P0 1200 MHz 8MB US-III+ 11.0 43 C 24 C
SB0/P1 1200 MHz 8MB US-III+ 11.0 42 C 24 C
SB0/P2 1200 MHz 8MB US-III+ 11.0 42 C 24 C
SB0/P3 1200 MHz 8MB US-III+ 11.0 41 C 25 C
SB2/P0 1200 MHz 8MB US-III+ 11.0 40 C 23 C
SB2/P1 1200 MHz 8MB US-III+ 11.0 41 C 23 C
SB2/P2 1200 MHz 8MB US-III+ 11.0 42 C 23 C
SB2/P3 1200 MHz 8MB US-III+ 11.0 41 C 23 C
    16 1200 MHz 8MB US-III+ 11.1 - -                  <- HERE !!!
    17 1200 MHz 8MB US-III+ 11.1 - -                  <- HERE !!!
    18 1200 MHz 8MB US-III+ 11.1 - -                  <- HERE !!!
    19 1200 MHz 8MB US-III+ 11.1 - -                  <- HERE !!!

IO Devices
     Bus   Freq
Brd  Type  MHz   Slot        Name                          Model
---  ----  ----  ----------  ----------------------------  --------------------
 0   pci    33         PCI0  pci108e,abba (network)        SUNW,pci-ce
 0   pci    33         PCI1  pci108e,abba (network)        SUNW,pci-ce
 0   pci    33         PCI2  scsi-pci1000,f (scsi-2)
 0   pci    33         PCI2  scsi-pci1000,f (scsi-2)
 0   pci    33         PCI3  lpfc-pci10df,f900 (scsi)      LP9002
 0   pci    33         PCI4  lpfc-pci10df,f900 (scsi)      LP9002
 0   pci    66            1  pci108e,abba (network)        SUNW,pci-ce
 0   pci    66            2  scsi-pci1000,21 (scsi-2)
 0   pci    66            2  scsi-pci1000,21 (scsi-2)
 0   pci    66            2  pci108e,abba (network)        SUNW,pci-ce
 0   pci    33            3  pci1095,646 (ide)
 0   pci    33            4  bootbus-controller-sgsbbc     SUNW,sgsbbc



Resolution
Resolution
The workaround for this situation is to shutdown the system and reconfigure-boot the system (boot -r). 
It is also recommended to make sure the picl patch is updated (see Patch ID 111792 ) on the system in question.
NOTE:  This issue was reported on Solaris 8 and ScApp 5.18.x, but it is not thought to occur on any other configuration.


Product
Sun Fire V1280 Server

Internal Comments
For internal Sun use only.

Refer to Bug ID 5102782 


prtdiag, SB, system board, environment, temperature, failed, boot -r, picl
Previously Published As
85710

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.