Solution  1003144.1 :   Sun Fire[TM] 880: SCSI error with luxadm download for onboard FCAL firmware  


Related Items
  • Sun Fire V880 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
204323


Symptoms
When upgrading the onboard FCAL firmware on a Sun Fire[TM] 880 and using the command:
# luxadm download -f <firmware_path> <enclosure_name>

Where:

  • <firmware_path> is the location of the firmware image on the system disk -- in this case, /usr/platform/SUNW,Sun-Fire-880/lib/images/int_fcbpl_fw.

  • <en closure_name> is the enclosure name assigned to the Sun Fire 880 internal storage array -- by default, FCloop. If you need to verify the enclosure name first, use the luxadm probe subcommand.

The following error message is encountered:

# luxadm download -f /usr/platform/SUNW,Sun-Fire-880/lib/images/int_fcbpl_fw FCloop
SCSI Error - Sense Byte:(0x2) Check condition
Error: Retry failed. - /usr/platform/SUNW,Sun-Fire-880/lib/images/int_fcbpl_fw.

The above error message is due to the system keyswitch being placed in the Locked position.



Resolution
To rectify this error, please change the keyswitch position to Normal.


Product
Sun Fire V880 Server

Sense Byte:(0x2) Check condition, luxadm download, int_fcbpl_fw, DPM
Previously Published As
42811

Change History
Date: 2005-04-04
User Name: 97961
Action: Approved
Comment: Publishing. No further edits.
Version: 3
Date: 2005-04-04
User Name: 97961
Action: Accept
Comment:
Version: 0
Date: 2005-04-04

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback