Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1003665.1
Update Date:2009-02-02
Keywords:

Solution Type  Problem Resolution Sure

Solution  1003665.1 :   Sun Fire[TM] V880 with low OpenBoot[TM] Prom will not print out location of failed dimms  


Related Items
  • Sun Fire V880 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
205177


Symptoms
with certain memory dimm failures and low revs of the OpenBoot[TM] Prom (OBP) the Sun Fire[TM] V880 will not boot and no failed memory dimms will be identified by POST or extended diagnostics. The only message seen is when the system tries to boot and fails. The error seen is "Corrected ECC Error" and the system drops back to the OK prompt.

Resolution
When the above conditions occurs there is no way to identified the failed dimms and no way of booting the system, not even from cdrom, except to replace the I/O board with one that has a higher rev OBP. Once the failed dimms has been identified and replaced, the original I/O pcb can be re-installed and the system booted at which time the OBP should be upgraded immediately to avoid future incidents of the same nature.

Additional Information
this problem was observed with OBP 4.10.8

Product
Sun Fire V880 Server

V880, OBP, boot, corrected, ECC Error
Previously Published As
81435

Change History
Date: 2005-05-05
User Name: 71396
Action: Approved
Comment: Performed final review of article.

Updated trademarking and product names.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.