Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1003665.1 : Sun Fire[TM] V880 with low OpenBoot[TM] Prom will not print out location of failed dimms
PreviouslyPublishedAs 205177 Symptoms with certain memory dimm failures and low revs of the OpenBoot[TM] Prom (OBP) the Sun Fire[TM] V880 will not boot and no failed memory dimms will be identified by POST or extended diagnostics. The only message seen is when the system tries to boot and fails. The error seen is "Corrected ECC Error" and the system drops back to the OK prompt. Resolution When the above conditions occurs there is no way to identified the failed dimms and no way of booting the system, not even from cdrom, except to replace the I/O board with one that has a higher rev OBP. Once the failed dimms has been identified and replaced, the original I/O pcb can be re-installed and the system booted at which time the OBP should be upgraded immediately to avoid future incidents of the same nature. Additional Information this problem was observed with OBP 4.10.8 Product Sun Fire V880 Server V880, OBP, boot, corrected, ECC Error Previously Published As 81435 Change History Date: 2005-05-05 User Name: 71396 Action: Approved Comment: Performed final review of article. Updated trademarking and product names. Attachments This solution has no attachment |
||||||||||||
|