Solution Type Problem Resolution Sure Solution 1004253.1 : PSH: Diagnosis Issue for T5120 and T5220 (FMD-8000-11)
PreviouslyPublishedAs 205881 Symptoms A PSH diagnosis message appears on the console with the MSG-ID FMD-8000-11 (The Solaris[TM] Fault Manager unable to determine message summary). The action recommended in the message: Run pkgchk-n SUNWfmd does not resolve the problem. Resolution On the Sun SPARC Enterprise T5120 and T5220, this PSH message may be caused by a known issue with a fault class name (SUNBUG: 6532872).
Refer to the MOS (Patches & Updates) Relief/Workaround The EVENT-ID is highlighted in the example below: SUNW-MSG-ID: FMD-8000-11, TYPE: Defect, VER: 1, SEVERITY: Minor EVENT-TIME: Fri Jun 15 00:06:22 EDT 2007 PLATFORM: SUNW,SPARC-Enterprise-T5120, CSN: -, HOSTNAME: wgs40-127 SOURCE: cpumem-diagnosis, REV: 1.6 EVENT-ID: e4cb7d73-b795-61d0-a232-ac5e017108ab DESC: A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to http://sun.com/msg/FMD-8000-11 for more information. AUTO-RESPONSE: The diagnosis has been saved in the fault log for examination by Sun. IMPACT: The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required. REC-ACTION: Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Cut and paste the EVENT-ID onto the following command: # fmdump -v -u EXAMPLE # fmdump -v -u e4cb7d73-b795-61d0-a232-ac5e017108ab TIME UUID SUNW-MSG-ID Jun 15 00:06:22.2007 e4cb7d73-b795-61d0-a232-ac5e017108ab FMD-8000-11 100% <fault class> Problem in: cpu:///cpuid=8/serial=5D67334847 Affects: cpu:///cpuid=8/serial=5D67334847 FRU: hc://:serial=101083:part=541215101/motherboard=0 Location: MB If the <fault class> is fault.cpu.ultraSPARC-T2.misc_regs then it is a result of the issue caused by CR 6532872 . The faulty FRU displayed is correct. In the example above, the FRU is the motherboard. Contact Sun support to replace the faulty FRU. If the <fault class> is not fault.cpu.ultraSPARC-T2.misc_regs then contact Sun support to diagnose the problem. Product Sun SPARC Enterprise T5120 Server Sun SPARC Enterprise T5220 Server Internal Comments Place Sun Internal-Use Only content here. This content will be published to internal SunSolve only.
PSH, FMD-8000-11, T5120, T5220, defect.sunos.fmd.nodiagcode Previously Published As 91179 Change History Date: 2011-05-04 User name: Dencho Kojucharov Action: Currency check (link updates) Comments: audited by Entry-Level SPARC Content Lead Date: 2009-11-17 User Name: 79977 Action: Updated Comment: Currency update, audited by Dencho Kojucharov, Entry-Level SPARC Content Lead Date: 2008-11-21 User Name: T230884 Action: Quality Review Date: 2007-10-22 User Name: 29589 Action: Update Canceled Comment: *** Restored Published Content *** whb - delete workng copy Version: 0 Date: 2007-10-22 User Name: 29589 Action: Update Started Comment: whb Version: 0 Date: 2007-10-22 User Name: 29589 Action: Approved Comment: Updated format. This document has been approved by Mark Bennett to be Free.This is part of the FMA initiative. Please do not change audience. Version: 6 Attachments This solution has no attachment |
||||||||||||
|