Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1005020.1
Update Date:2009-12-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1005020.1 :   Sun StorEdge[TM] S1 Array / Sun Fire[TM] V440 Server: Attaching the Array to the Server's Onboard SCSI Controller  


Related Items
  • Sun Fire V440 Server
  •  
  • Sun Storage S1 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>JBOD Disk
  •  

PreviouslyPublishedAs
207040


Symptoms
A poor SCSI negotiation speed occurs when a Sun StorEdge[TM] S1 array is
attached to a Sun Fire[TM] V440 server's onboard SCSI external port.

You can check the negotiation speed with the following:
# prtpicl -v | grep sync
:no-dma-interrupt-sync
:target0-sync-speed        320000
:target1-sync-speed        320000
:target2-sync-speed        320000
:target0-sync-speed        40000
:target1-sync-speed        40000
:target2-sync-speed        40000
In the example, the second lot of disks are running at 40000, but the
onboard SCSI controller in the Sun Fire V440 server is an Ultra320 SCSI,
and in the Sun StorEdge S1 array is an Ultra160 SCSI.  Therefore, the
minimum speed should be 16000.
Also, the following messages appear during boot:
NOTICE: mpt1: fault detected in device; service still available
NOTICE: mpt1: Connected command timeout for Target 0
WARNING: /pci@1f,700000/scsi@2,1 (mpt1):
Target 0 reducing sync. transfer rate


Resolution
Add the following to the /kernel/drv/mpt.conf file and then reboot:
   name="mpt" parent="/pci@1f,700000"
unit-address="2,1"
scsi-options=0x1ff8;
Compare the prtpicl output following this change to the prtpic1 output
shown previously:
# prtpicl -v | grep sync
:no-dma-interrupt-sync
:target0-sync-speed        320000
:target1-sync-speed        320000
:target2-sync-speed        320000
:target0-sync-speed        160000
:target1-sync-speed        160000
:target2-sync-speed        160000
You should also use the latest patches for the Sun Fire V440 onboard SCSI
controller:
Solaris[TM] 8 Operating System - 115274 and 115275
Solaris 9 Operating System     - 116532


Product
Sun Fire V440 Server
Sun StorageTek S1 Array
Sun Fire V440
146 GB 10000 rpm SCSI Hard Disk Drive for Netra st A1000/D1000 and Sun StorageTek S1
146 GB 10000 rpm SCSI Hard Disk Drive for Sun Fire V440

Internal Comments
Audited/updated 12/03/09 - Ian.Macdonald@Sun.COM, Entry Level SPARC Content Team Member




v440, S1
Previously Published As
75885

Change History
Date: 2007-06-28
User Name: 7058
Action: Add Comment
Comment: Notes for Normalizaton:
This document is referenced by: 80089 which references 89047
Subset Root path:
75885-->80089-->89047-->89034-->89031-->89050
Project: Minnow Normalization
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback