Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1005619.1
Update Date:2011-03-18
Keywords:

Solution Type  Problem Resolution Sure

Solution  1005619.1 :   SL8500 - Problems Upgrading SL8500 Code Direct Attached  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
207801


Applies to:

Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 18-Mar-2011.

Symptoms

Problems Upgrading SL8500 Code Direct Attached.
Several sites have reported issues upgrading SL8500 Library Controller Code and  SLC (StreamLine Library Console) Code while being directly attached to port 2B on the HBC card.
Code load begins and then stops; the Ethernet LED stops flashing, the connect status turns yellow and then turns red.

Cause

The root cause was drivers on the remote PC.

Solution

Steps to Follow
It is recommended if a direct attach code upgrade is needed via a cross-over cable the IP connection speed be changed to 10Mb Half-Duplex to help stabilize the connection.

Recommended setup for PC's directly attached to port 2B via crossover cable:

Example configuration change with Windows XP Professional.

- Start
- Control Panel
- Network Connections
- Local Area Connections
- Configure network controller card; e.g. BroadCom 570x Gigabit Integrated Controller #2
- Advance Tab
- In properties window select "Speed & Duplex"
- Set Value to 10Mb Half

Another solution was reported by temporarily installing an IP switch between port 2B and the remote PC.





Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.