Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1007577.1
Update Date:2009-09-21
Keywords:

Solution Type  Problem Resolution Sure

Solution  1007577.1 :   Sun Enterprise[TM] 450 during power up OBP hangs, last message "Environmental monitoring: enabled"  


Related Items
  • Sun Enterprise 450 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
210483


Symptoms

Sun Enterprise 450 completes POST successfully with STATUS=PASSED, then OBP starts probing CPU's and memory

normally until the system hangs, last message " Environmental monitoring: enabled "

Sample output: . from serial port ttya, normal post messages, no problems detected

0>STATUS=PASSED

Power On Selftest Completed

Status = 0000.0000.0000.0000 ffff.ffff.f00b.4860 ffdf.ffff.0bd1.1111

POST Reset

CPU0 has assumed the role of Boot CPU

@(#) Sun 450 3.7 Version 107 created 1998/02/19 17:54

Online: CPU0 Blackbird (v1.1) 3:1 2048KB 2-2 ECache MCap 13

Online: CPU1 Blackbird (v2.0) 3:1 2048KB 2-2 ECache MCap 13

Online: CPU2 Blackbird (v2.0) 3:1 2048KB 2-2 ECache MCap 13

Online: CPU3 Blackbird (v1.1) 3:1 2048KB 2-2 ECache MCap 13

Setting system ECache size to 2048KB

Clearing DTAGS...Done

Clearing E-Cache Tags...Done

Clearing I/D TLBs...Done

Probing Memory...Done

HiMem base = 0000.0000.0000.0000 size = 0000.0000.2000.0000

Clearing Memory...including Unix Retained Memory...Done

MMUs ON

Copying ROM to RAM...Done

ROM PC = 0000.01ff.f000.4b40

RAM PC = 0000.0000.0000.4b88

RAM CRC = 0000.0000

2ea7.1606; ROM CRC = 0000.0000.2ea7.1606

Decompressing into Memory...0000.0000.0004.523c (277KB)...Done

Size = 0000.0000.0008.4b00 (531KB)

Starting Forth kernel at 0000.0000.f005.6b68

ttya initialized

Memory in 2 - way interleave configuration

...Bank #0 64 + 64 + 64 + 64 : 256 MB

...Bank #1 64 + 64 + 64 + 64 : 256 MB [Available 512MB @ 0 ]

...Bank #2 0 + 0 + 0 + 0 : 0 MB [Not In Use]

...Bank #3 0 + 0 + 0 + 0 : 0 MB [Not In Use]

Environmental monitoring: enabled <------- system hung, last message outputed



Resolution

Suspect a defective fan/interlock cable assembly [FRU] 530-2305 or

check the seating of fan/interlock cable assembly at connector J0307 (lower right) of Power Distribution board 501-3100



Product
Sun Enterprise 450 Server

Internal Comments

Email james.bain@sun.com


Previously Published As
47925

Change History
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : Robin Dole
comment :
fixed tages. fixed internal section.

date : May 12, 2003



updated by : Robin Dole
comment : No comment
date : May 12, 2003



updated by : Lon Maddy
comment : Checked information in doc against information I had,
everything looks good.
date : May 6, 2003



updated by : James Bain
comment : srdb ready for evaluation.
date : May 3, 2003



updated by : James Bain
comment : Article created.
date : Oct 10, 2002
Version: 0
Product_uuid
29656238-0a18-11d6-91d9-a4e449afd809|Sun Enterprise 450 Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback