Solution Type Problem Resolution Sure Solution 1008296.1 : Sun Fire [TM] X2100 M2 Server BIOS eventlog shows Axial front fan is not present or has stopped.
PreviouslyPublishedAs 211360 Symptoms After a reboot the Sun Fire [TM] X2100 M2 Server may display an error and is found in the BIOS IPMI event log: " Axial front fan is not present or has stopped " The error was not there at initial power-up. When physically checking the fan it shows it is spinning. Resolution On the X2100 M2 there are two axial fan connectors but only one fan unit for the PCI slots. One connector is white and the other black. BIOS/SP version 3A15/2.91 does not monitor the fan speed on the white connector but the connector still provides power so that the fan still functions. Before replacing this fan due to the error make sure that the fan is correctly connected to the black connector. Product Sun Fire X2100 M2 Server Internal Comments The following is strictly for the use of Sun employees: See also CR 6564367 Issue is also documented on TSC website:
Under the heading ELOM reports axial fan is In addition: We have received a conflicting information from field that the X2100M2, eventlog, axial, front, fan, not present Previously Published As 87351 Change History This link in the Intenal Comments statement is broken http://systems-tsc/twiki/bin/view/Products/ProdIssuesSunFireX2100M2 Date: 2007-06-15 User Name: 71396 Action: Approved Comment: Performed final review of article. No changes required. Attachments This solution has no attachment |
||||||||||||
|