Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1009706.1 : How to clear BMC error
PreviouslyPublishedAs 213347 Symptoms If you see the following error on system console of a Sun Fire[TM] V20z/V40z then you need to clear the Error Log. ERROR 02A2: BMC System Error Log (SEL) Full. Resolution If the above message appears during POST, perform the following steps to run BIOS setup and delete the System Event Log: 1. Boot the server and press the F10 key when prompted to run BIOS Setup. 2. Select the "Advanced" menu. 3. Scroll down to "IPMI" and press the ENTER key. 4. Scroll down to the System Event Log and press the ENTER key. (To verify the existing Event Logs) 5. At the "Clear System Event Log" selection, press the ENTER key to toggle between "Enable" and "Disable." 6. Select "Enable." 7. Press the F10 key to Save the changes and exit the BIOS Setup. A future System ROM upgrade will allow the server to continue POST without user input if the System Event Log becomes full. This advisory will be updated when additional information becomes available. Product Sun Fire V40z Server Sun Fire V20z Server Internal Comments Audited/updated 11/17/09 - James.Carter@Sun.COM, x64 Content Team BMC, v20z, v40z, console, BIOS Previously Published As 88448 Change History Date: 2007-04-13 User Name: 71396 Action: Approved Comment: Publishing Version: 3 Date: 2007-04-13 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2007-04-13 User Name: 35516 Action: Approved Comment: Technical correct and easy to understand please publish Version: 0 Attachments This solution has no attachment |
||||||||||||
|