Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1010567.1
Update Date:2009-09-13
Keywords:

Solution Type  Problem Resolution Sure

Solution  1010567.1 :   Sun Fire[TM] V240 bge IF has high error rate at Cisco Catalyst WS-C4006  


Related Items
  • Sun Fire V240 Server
  •  
  • Sun Fire V210 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
214540


Symptoms
A link between a Sun Fire [TM] V240 with a bge interface and a Cisco Catalyst
WS-C4006 is not established well as long as the ports
- are left in default configuration or
- are set to 1Gb/s full-duplex forced (autonegotiation off).
The link shows poor performance due to high input packet errors at the bge
interface.
# netstat -i 10
input   bge0      output           input  (Total)    output
packets errs  packets errs  colls  packets errs  packets errs  colls
29804   25911 56433   0     0      29881   25911 56510   0     0
29064   23963 54946   0     0      29064   23963 54946   0     0


Resolution
Set the bge interface to 1Gb/s full-duplex fixed with autonegotiation
enabled at the SF V240 and also enable autonegotiation at the Cisco Catalyst
WS-C4006 port:
Example for bge0:

# ndd -set /dev/bge0 adv_1000fdx_cap 1
# ndd -set /dev/bge0 adv_1000hdx_cap 0
# ndd -set /dev/bge0 adv_100fdx_cap 0
# ndd -set /dev/bge0 adv_100hdx_cap 0
# ndd -set /dev/bge0 adv_10fdx_cap 0
# ndd -set /dev/bge0 adv_10hdx_cap 0
# ndd -set /dev/bge0 adv_autoneg_cap 1

For more information on bge interface read Technical Instruction <Document: 1001843.1> "bge Gigabit Ethernet - First Checks".


Product
Sun Fire V240 Server
Sun Gigabit Ethernet PCI Adapter
Sun Fire V210 Server

Internal Comments
Internal PTS Product Page:
http://pts.emea/comms/products/bge/

bge, Cisco, Catalyst
Previously Published As
72197

Change History
Date: 2006-01-17
User Name: 18392
Action: Update Canceled
Comment: *** Restored Published Content *** SSH Audit
Version: 0
Date: 2006-01-17
User Name: 18392
Action: Update Started
Comment: SSH Audit
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.