Solution Type Problem Resolution Sure Solution 1014101.1 : SL8500 - Sbot Initialization Failure Due to Rail Terminator Problem
PreviouslyPublishedAs 220385 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential for Partners and Oracle Support personnel
Applies to:Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later [Release: N/A and later]All Platforms Checked for relevance on 16-Mar-2011. SymptomsRobot will not initializeSbot fail initialization Init failure Changes{CHANGE}Cause{CAUSE}SolutionResolutionOne of the two blade contacts was not inserted into the mating socket properly. This is not readily apparent but can be found upon close inspection. This affects only the second generation of rail terminators denoted by the use of the HBQ card. It is also possible to have intermittent rail communication errors if the terminators are not assembled correctly. The part number for the HBQ terminator card is 313823202. See the attached for additional information. Product Sun StorageTek SL8500 Modular Library System Internal Comments Oracle Review 1/19/10, Glen Foley Rail Terminator, SL8500, Part Number, HBQ terminator card Previously Published As STKKB60402 Attachments This solution has no attachment |
||||||||||||
|