Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1015813.1
Update Date:2010-10-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  1015813.1 :   Message SLS0662I LMU Response Error - xx,xxx,28,13 and SLS0660I ERR BCST  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
  • Sun StorageTek Host Software Component (HSC) for Fujitsu MSP.
  •  
Related Categories
  • GCS>Sun Microsystems>Storage Software>Mainframe Software
  •  

PreviouslyPublishedAs
224607


Applies to:

Sun Storage Host Software Component (HSC) - Version: All Versions and later   [Release: and later ]
Sun Storage SL8500 Modular Library System - Version: Not Applicable and later    [Release: NA and later]
IBM z/OS on System z

Symptoms

SLS0660I error messages received every 5 minutes.
SLS0660I ERR BCST - (01400114005C04)
SLS0662I LMU Response error - xx,xxx,28,13

Changes

    

Cause

The 28,13 on the SLS0662I indicates Invalid Broadcast and Invalid LSM respectively.  For the 'C04' at the end of the SLS0660I message, the 'C' indicates Open Door and the '04' is the LSM ID.  This means HSC is receiving a broadcast from the LSM ID but HSC has no knowledge of an LSM with that number.  The SLS0660I can be issued more than once with a different number at the end of the string to indicate a different LSM ID.

Solution

This problem needs to be investigated by the CSE from the hardware perspective.  It is the hardware sending these broadcasts to HSC.

For example, if there were two SL8500s connected but one was removed, verify that all cables and PTPs between the two SL8500s are disconnected.   The problem may also be a config file in the SL8500 that needs to be cleared.  The CSE should be able to do that or they can contact Tape Hardware Support for assistance.  SL8500 microcode has also been a solution to this problem.


Previously Published As STKKB79865

Product_uuid
817ba1d5-2831-4203-b6b0-c682df25a7d8