Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1016322.1 : VTSS fails to initialize during HSC/VTCS start-up after SLS6675E with RC=08
PreviouslyPublishedAs 225794 Symptoms VTSS fails to initialize during HSC/VTCS start-up Message SLS6675E occurs for one or more VTDs Lack of SLS6632I "VTSS server ready" message for each VTSS SLS6632I does not occur if only one VTSS is configured Message SLS6670E may also be issued SLS6675E VTSS:nnnnnnnn VTD:dddd CONFIGURATION ERROR RC=6A40FF0C SLS6675E VTSS: nnnnnnnn VTD: dddd CONFIGURATION ERROR RC=00000008 SUBSYSTEM INFO: 99999999/mmmm/ooooooo SLS6698I ECAM I/O ERROR ON VTD dddd SLS6670E RTD rrrrrrrr FAILED INITIAL CONFIGURATION WITH CC=254 RC=0 Resolution This problem generally occurs with a new install of a VTSS when the production arrays within the VTSS itself were not configured. The CSE needs to configure the production arrays within the VTSS subsystem. After that has been completed, then stop and restart HSC/VTCS. Product Sun StorageTek VTCS Sun StorageTek Virtual Storage Manager System Internal Comments The Knowledge Work Queue for this article is KNO-STO-MAINFRAME_LIB_MGMT_SW. Tech Review history Audited/updated 02/13/2010 - [regina.hodel@sun.com], Mainframe SW Content Team - validated still current, made minor changes to statement order VSM, VTSS, VTCS, VTD, ECAM, install, initialization, SLS6675E, configuration error, 6A40FF0C, SLS6698I, ECAM I/O error, SLS6670E, initial configuration Previously Published As STKKB75767 Attachments This solution has no attachment |
||||||||||||
|