Solution  1017580.1 :   Using "cfgadm -c configure" and diag-level=mem2 may fail on Sun Fire[TM] V1280 and Netra[TM] 1280  


Related Items
  • Sun Netra 1280 Server
  •  
  • Sun Fire V1280 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  

PreviouslyPublishedAs
228732


Symptoms
Using "cfgadm -c configure <FRU>" and a diag-level of mem2 on a Sun Fire
v1280 or Netra 1280 system can cause the following message to occur "sgfru
ioctl 0xf handle 0xc1 failed: Connection timed out".

This is due to a Solaris[TM] to SC mailbox management issue that causes
Solaris to send messages to the SC while the SC is blocked, running LPOST
on the requested board. Solaris times out before the SC finishes running
POSt and can service the new messages.

Resolution
To avoid mailbox timeouts in this scenario, set the sgsbbc driver's minimum
and default time-out to 24 hours or greater. For other diag-levels, smaller
values can be used.

As root edit /etc/system:

set sbbc_mbox_default_timeout = 86700
set sbbc_mbox_min_timeout = 86700

Product
Netra 1280 Server
Sun Fire V1280 Server

Internal Comments
See BugID 4854333

sgfru, ioctl, 0xf, handle, 0xc1, failed:, Connection, timed, out
Previously Published As
74637

Change History
Date: 2004-03-17
User Name: 11511
Action: Approved
Comment: Doc ok to publish.
Version: 0
Date: 2004-03-15
User Name: 11511
Action: Accepted
Comment:
Version: 0
Date: 2004-03-10
User Name: 76225
Action: Approved
Comment: Clarified some info. Good content.
Version: 0
Date: 2004-03-08
User Name: 99865
Action: Approved
Comment: please review
Version: 0
Date: 2004-03-08
User Name: 99865
Action: Created
Comment:
Version: 0
Product_uuid
e41a7084-3dbf-472d-918b-efb50dcbc220|Netra 1280 Server
6a74b2f9-bbd8-4b2c-870d-b6b73d6e224f|Sun Fire V1280 Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback