Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1019051.1
Update Date:2010-05-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  1019051.1 :   SL8500 - Pass Thru Port Initialization Failures  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
233801


Applies to:

Sun Storage SL8500 Modular Library System
All Platforms

Symptoms

If the PTP is not able to trip both sensors during initialization, the PTP module will not come ready.

Cause

In a limited number of cases it has been due to an improperly adjusted sensor.

The failure mode can be seen in the error log with an error similar to “ptp,
/usr/local/bin/Ptpif, error, 0000, 5017, "Director - initResponse()
cmo_init_ptp(): SRV Init PTP failed; cmo_init_recover_ptp(): Gate Unknown -
Slide Path/Sensor Check Failed; Sweep Slide Failed; End of Text"”.

Refer to the attached file to show the sensor location.

Solution

Resolution
To resolve the issue, remove the PTP assembly, and adjust the sensors so that when the PTP is extended the sensor is tripped on the side the array is extended towards. The sensors can be found on the underside of the PTP assembly.




Product
Sun StorageTek StreamLine SL8500

SL8500, Pass Thru Port, PTP, Sensors, 5017
Internal Comments
Oracle review 11/09/09.


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.