Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1132724.1 : VTL - Direct connect monitor not displaying from video port
In this Document
Applies to:Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 - Release: 1.0 to 2.0Information in this document applies to any platform. Symptoms- Direct connect monitor does not work- V40z is not displaying out the back video port ChangesN/ACauseThe video on these V40z servers have been redirected to the service processor port rather than to the video on the back of the server node.SolutionLog into Solaris command line (as root) and enter:# eeprom console=screen If you want the console back to the SP, enter: # eeprom console=ttya Additional Information New install V40z VTL Plus Monitor Attachments This solution has no attachment |
||||||||||||
|