Solution  1269395.1 :   Sun Fire[TM] V1280, E2900, Netra[TM] 1280, and 1290 Servers: IB_SSC fails POST after "Not enough memory" message  


Related Items
  • Sun Fire V1280 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Netra 1280 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  


When POST encounters "Not enough memory to allocate buffer of XXXXXX bytes." the next "Excluded unusable, unlicensed, failed or disabled board: /N0/IB6" may be just a side effect that an SC reboot will fix.

In this Document
  Symptoms
  Changes
  Cause
  Solution


Applies to:

Sun Netra 1280 Server - Version: Not Applicable and later   [Release: NA and later ]
Sun Netra 1290 Server - Version: Not Applicable and later    [Release: NA and later]
Sun Fire V1280 Server - Version: Not Applicable and later    [Release: NA and later]
Sun Fire E2900 Server - Version: Not Applicable and later    [Release: NA and later]
Information in this document applies to any platform.

Symptoms

The "showlogs" command on the SC or the domain's "lw8" messages show these log entries:


11/14/10 2:46:39 AM Domain Reboot A: Initiating keyswitch: on, domain A.
11/14/10 2:46:39 AM Domain Reboot A: Initiating keyswitch: on, domain A.
11/14/10 2:47:16 AM Not enough memory to allocate buffer of 431300 bytes.
11/14/10 2:47:22 AM Excluded unusable, unlicensed, failed or disabled board: /N0/IB6
11/14/10 2:47:22 AM No usable Io board in domain.
11/14/10 2:47:22 AM Reboot failed.
11/14/10 2:51:20 AM Domain Shell - A: poweroff: Initiating keyswitch: off, domain A.



The next restarts will exclude /N0/IB6, too, making the system unusable.

......
{/N0/IB6/P0} Unknown
{/N0/IB6/P1} Unknown

......

Changes

This happens typically after a long uptime of the SC and frequent reboots of the domain.

Cause

The SC's memory is too fragmented to allocate the required amount of memory.
This leads to POST failing while the IB_SSC is tested.
As a consequence the I/O part, /N0/IB6, is disabled.

Solution

Reboot the SC to clear the memory fragmentation.

Use:

       lom> resetsc