Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1319397.1
Update Date:2011-05-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1319397.1 :   SL8500 - Elevator Tube is Damaged Due to Failed Roller  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  




In this Document
  Symptoms
  Cause
  Solution


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Confidential for Partners and Oracle Support personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Symptoms

Elevator tube damaged by failed roller.

Cause

Roller on elevator assembly has failed.

Solution

In the event that the elevator tube is damaged by a failed roller, the tube can be rotated to present a smooth surface to the replacement rollers. This should remove the requirement to replace an elevator tube.

For reference, the part numbers of the rollers and spring roller assembly are as follows:
419889103 - ROLLER,3/4 OD
419838103 - SPRING,Z ROLLER PRELOAD SUBASSY
At this time the 1" roller used on the H-Bots is not available as a FRU. Engineering has decided to have the field replace an H-Bots if any of the 1" rollers (Rail contacting rollers) are defective.