Solution Type Sun Alert Sure Solution 1000059.1 : T3+ Array In Loop Mode Goes Offline From Fabric Switch After 'volslice remove' is Run
PreviouslyPublishedAs 200075 Product Sun StorageTek T3+ Array Bug Id <SUNBUG: 6577650> Date of Workaround Release 21-SEP-2007 Impact When a T3+ array with firmware 3.2.3.3 (and above) is attached to a Fabric switch and a volume slice is removed using 'volslice remove', the complete loop goes offline and all devices (LUNs) become unavailable. Contributing Factors This issue can occur in the following release: SPARC Platform
Notes:
To determine the firmware revision on the T3+ array, log in to the T3+ and run the following command: t3m:/:<1>ver T3B Release 3.2.6 Mon Feb 5 01:00:35 MST 2007 (129.158.142.117) Copyright (C) 1997-2006 Sun Microsystems, Inc. All Rights Reserved.
Symptoms After 'volslice remove' is run, errors similar to the following are reported to the attached host: Jun 20 17:00:34 v4u-880h fctl: [ID 517869 kern.warning] WARNING: fp(5)::N_x Port with D_ID=620ce8, PWWN=50020f2300 009720 disappeared from fabric Jun 20 17:00:34 v4u-880h fctl: [ID 517869 kern.warning] WARNING: fp(4)::N_x Port with D_ID=620ce8, PWWN=50020f2300 009720 disappeared from fabric Jun 20 17:00:35 v4u-880h fctl: [ID 517869 kern.warning] WARNING: fp(4)::N_x Port with D_ID=620ae4, PWWN=50020f2300 00921a disappeared from fabric Jun 20 17:00:35 v4u-880h fctl: [ID 517869 kern.warning] WARNING: fp(5)::N_x Port with D_ID=620ae4, PWWN=50020f2300 00921a disappeared from fabric Workaround To work around this issue, set the 'fc_topology' to 'fabric_p2p' on the array by doing the following (logged in to the array): t3m:/:<6>sys fc_topology fabric_p2p WARNING - Changing topology will disrupt i/o traffic. Continue ? [N]: y
Resolution A final resolution is pending completion. Previously Published As 103074 Internal Comments Internal Contributor/submitter Rajib.Dutta@Sun.COM Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer Huy.Nguyen@sun.com Internal Services Knowledge Engineer david.mariotto@sun.com Internal Escalation ID 1-21897382 Internal Sun Alert Kasp Legacy ID 103074 Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> HA-Failure Significant Change Date: 2007-09-21 Avoidance: Workaround Responsible Manager: Michael.s.Hayward@sun.com Original Admin Info: [WF 21-Sep-2007, dave m: no review comments, send for release] [WF 20-Sep-2007, dave m: draft created, send for review] Product_uuid 2a714b10-0a18-11d6-86e2-d56b387d4fbf|Sun StorageTek T3+ Array Attachments This solution has no attachment |
||||||||||||
|