Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1000296.1
Update Date:2011-02-28
Keywords:

Solution Type  Sun Alert Sure

Solution  1000296.1 :   For Sun StorEdge 3310, Running SSCS and sccli(1M) In-Band at the Same Time May Cause SCSI Errors  


Related Items
  • Sun Storage 3310 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
200411


Product
Sun StorageTek 3310 SCSI Array

Bug Id
<SUNBUG: 5024472>

Date of Workaround Release
10-MAY-2004

Date of Resolved Release
13-SEP-2005

Impact

On Sun StorEdge 3310, running Sun StorEdge Configuration Service (SSCS) in-band and sccli(1M) in-band at the same time may cause SCSI errors on servers. This can cause I/O issues and the server may require a reboot.

Note: SSCS is a graphical means of managing the SE3XXX family of products. sccli(1M) is the Command Line Interface (CLI) means of managing the same products.


Contributing Factors

This issue can occur on the following platform:

SPARC Platform

  • Sun StorEdge 3310 SCSI Array without firmware 4.13b (as delivered in patch 113722-11)

with the following:

  • Sun StorEdge Configuration Service (SSCS) and sccli(1M)

Note: SSCS, sccli(1M) and the glm(7D) driver are not Solaris version dependent.

This issue occurs when the following two conditions are met:

1. At least the following two daemons must be running on the monitoring server, verified by using the following command:

$ ps -ef | grep ss
root   370     1  0 08:08:21 ?        0:05 /usr/sbin/ssserver
root   374     1  0 08:08:21 ?        0:36 /usr/sbin/ssmon

2. In-band operation has to have been selected for the GUI which can be verified using the following command:

% grep "PRIAGENT_OVER_INBAND=" /var/opt/SUNWsscs/ssagent/ssagent.cfg
PRIAGENT_OVER_INBAND=0

Note: 0 = in-band selected (default); 1 = out-of-band selected


Symptoms

Should the described issue occur, messages similar to the following will be logged to the "var/adm/messages" file:

    Oct 20 13:40:00 v4u-v240a glm: [ID 655122 kern.warning] WARNING:
    ID[SUNWpd.check_intcode.6006]
    Oct 20 13:40:00 v4u-v240a scsi: [ID 107833 kern.warning] WARNING:
    /pci@1c,600000/scsi@2,1 (glm1):
    Oct 20 13:40:00 v4u-v240a Resetting scsi bus, data overrun: got too
    much data from target from (4,0)
    Oct 20 13:40:00 v4u-v240a genunix: [ID 408822 kern.info] NOTICE:
    glm1: fault detected in device; service still available
    Oct 20 13:40:00 v4u-v240a genunix: [ID 611667 kern.info] NOTICE:
    glm1:Resetting scsi bus, data overrun: got too much data from
    target from (4,0)
    Oct 20 13:40:00 v4u-v240a scsi: [ID 107833 kern.warning] WARNING:
    /pci@1c,600000/scsi@2,1 (glm1):
    Oct 20 13:40:00 v4u-v240a Target 4 reducing sync. transfer rate
    Oct 20 13:40:00 v4u-v240a glm: [ID 923092 kern.warning] WARNING:
    ID[SUNWpd.glm.sync_wide_backoff.6014]
    Oct 20 13:40:00 v4u-v240a scsi: [ID 107833 kern.warning] WARNING:
    /pci@1c,600000/scsi@2,1 (glm1):
    Oct 20 13:40:00 v4u-v240a got SCSI bus reset
    Oct 20 13:40:00 v4u-v240a genunix: [ID 408822 kern.info] NOTICE:
    glm1: fault detected in device; service still available
    Oct 20 13:40:00 v4u-v240a genunix: [ID 611667 kern.info] NOTICE:
    glm1: got SCSI bus reset
    Oct 20 13:40:20 v4u-v240a glm: [ID 655122 kern.warning] WARNING:
    ID[SUNWpd.check_intcode.6006]
    Oct 20 13:40:20 v4u-v240a scsi: [ID 107833 kern.warning] WARNING:
    /pci@1c,600000/scsi@2,1 (glm1):
    Oct 20 13:40:20 v4u-v240a Resetting scsi bus, data overrun: got too
    much data from target from (4,0)
    Oct 20 13:40:20 v4u-v240a genunix: [ID 408822 kern.info] NOTICE:
    glm1: fault detected in device; service still available
    Oct 20 13:40:20 v4u-v240a genunix: [ID 611667 kern.info] NOTICE:
    glm1: Resetting scsi bus, data overrun: got too much data from
    target from (4,0)

 


Workaround

To work around this issue, run either SCCS or sscli(1M) "out-of-band". The document "Sun StorEdge 3000 Family Configuration Service 1.5 User's Guide" part number 817-3337-12 page 103, chapter title: "To Use Out-of-Band Management," describes how to configure out-of-band management.


Resolution

This issue is addressed on the following platform:

SPARC Platform

  • Sun StorEdge 3310 SCSI Array with firmware 4.13b (as delivered in patch 113722-11 or later)


Modification History
Date: 13-SEP-2005

13-Sep-2005:

  • Update Contributing Factors and Resolution sections


References

<SUNPATCH: 113722-11>

Previously Published As
101495
Internal Comments





Internal Contributor/submitter
younan.sarkis@sun.com

Internal Eng Business Unit Group
NWS (Network Storage)

Internal Eng Responsible Engineer
neill.wood@sun.com

Internal Services Knowledge Engineer
david.mariotto@sun.com

Internal Escalation ID
551244

Internal Resolution Patches
113722-11

Internal Sun Alert Kasp Legacy ID
101495, 57558 (Sun Alert)

Internal Sun Alert & FAB Admin Info
Critical Category: Availability ==> Pervasive
Significant Change Date: 2004-05-10, 2005-09-13
Avoidance: Patch, Workaround
Responsible Manager: bagher.vahdatinia@sun.com
Original Admin Info: [WF 13-Sep-2005, Dave M: resolution patch released; re-release as Resolved]
This document has been imported from KMS Creator and may need adjustment before re-publishing.

This imported document has been reviewed/adjusted by:
Review Name:
Review Date:

Original KMS Creator attributes below:

--- PLEASE DO NOT MAKE ANY CHANGES BELOW THIS LINE! ---

Sun Alert ID: 57558
Synopsis: For Sun StorEdge 3310, Running SSCS and sccli(1M) In-Band at the Same Time May Cause SCSI Errors
Category: Availability
Product: Sun StorEdge, 3310 SCSI Array
BugIDs: 5024472
Avoidance: Workaround
State: Committed
Date Released: 10-May-2004
Date Closed:
Date Modified:
Escalation IDs: 551244
Pending Patches:
Resolution Patches:
FIN:
FCO:
Date Submitted: 06-May-2004
Submitter: younan.sarkis@sun.com
Responsible Engineer: neill.wood@sun.com
Responsible Manager: bagher.vahdatinia@sun.com
CTE group: PTS NWS EMEA
Responsible Writer: david.mariotto@sun.com
Distribution: Contract SunSolve

Workflow History:

WF State: Issued, 10-May-2004, David Mariotto
WF Note: released

WF State: Draft, 10-May-2004, David Mariotto
WF Note: sent for signoff, approved by PTS


WF State: Draft, 07-May-2004, David Mariotto
WF Note: sending for review, return by Monday noon

WF State: Draft, 07-May-2004, David Mariotto
WF Note: Article created.

Exported from KMS Creator Sat May 21 09:10:14 2005 GMT, olaf.reineke@sun.com
Internal SA-FAB Eng Submission
For Sun StorEdge 3310, Running SSCS and sccli(1M) In-Band at the Same Time May Cause SCSI Errors

Product_uuid
3db30178-43d7-4d85-8bbe-551c33040f0d|Sun StorageTek 3310 SCSI Array

References

SUNPATCH:113722-11

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback