Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000500.1 : Dual-Bus Sun StorEdge 3310 JBOD Configurations May Lose SCSI Termination in a Multi-Initiator Environment
PreviouslyPublishedAs 200639 Product Sun StorageTek 3310 SCSI Array Bug Id <SUNBUG: 4818874> Date of Resolved Release 17-JUN-2004 Impact Failover capability may be compromised when using the Sun StorEdge 3310 JBOD array in a multi-initiator environment. Contributing Factors This issue can occur with the following configurations :
This issue only occurs in multi-initiator SCSI environments. (for example, in a Sun Cluster environment) when a host connected to the "IN" port loses power. Notes: Sun StorEdge 3310 JBOD arrays in a single-bus configuration and Sun StorEdge 3310 RAID arrays are not affected. The SE 3310 JBOD disk array relies on the cluster nodes to provide SCSI bus termination. As termination power is not supplied from the array's "IN" ports, if the system connected to these loses power, SCSI bus termination will be lost. This in turn may result in the remaining host losing access to the shared storage on that SCSI bus. Symptoms The symptoms for loss of SCSI bus termination will vary depending on the length of the SCSI bus, the number of devices connected to the bus, and the environment it is installed in. Common errors for loss of termination include SCSI bus phase errors and devices dropping their transfer rates. In extreme cases, access to the devices may be lost completely. Workaround To work around the described issue, do not use the dual-bus SE 3310 array in a multi-initiator environment. Resolution All known cases of this issue have been addressed. Dual-Bus Sun StorEdge 3310 JBOD configurations in a multi-initiator environment is supported with the -02 revision of the SE3310 JBOD I/O module, Sun part number 370-5396. Modification History Date: 17-JUN-2004
Previously Published As 101223 Internal Comments
Internal Contributor/submitter James.MacFarlane@sun.com Internal Eng Business Unit Group OP/N1 RPE (Operating Platforms/N1 Revenue Product Engin.) Internal Eng Responsible Engineer James.MacFarlane@sun.com Internal Services Knowledge Engineer jeff.folla@sun.com Internal Escalation ID 544126 Internal Sun Alert Kasp Legacy ID 101223, 52687 (Sun Alert) Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Pervasive Significant Change Date: 2003-04-03 Avoidance: Workaround Responsible Manager: Chris.Armes@sun.com Original Admin Info: This document has been imported from KMS Creator and may need adjustment before re-publishing. This imported document has been reviewed/adjusted by: Review Name: Review Date: Original KMS Creator attributes below: --- PLEASE DO NOT MAKE ANY CHANGES BELOW THIS LINE! --- Sun Alert ID: 52687 Synopsis: Dual-Bus Sun StorEdge 3310 JBOD Configurations May Lose SCSI Termination in a Multi-Initiator Environment Category: Availability Product: Sun StorEdge 3310 Disk Array BugIDs: 4818874 Avoidance: Workaround State: Resolved Date Released: 03-Apr-2003 Date Closed: 17-Jun-2004 Date Modified: 17-Jun-2004 Escalation IDs: 544126 Pending Patches: Resolution Patches: none FIN: FCO: Date Submitted: 01-Apr-2003 Submitter: James.MacFarlane@sun.com Responsible Engineer: James.MacFarlane@sun.com Responsible Manager: Chris.Armes@sun.com CTE group: Solaris Sustaining Responsible Writer: jeff.folla@sun.com Distribution: Public SunSolve Workflow History: WF State: Issued, 17-Jun-2004, Jeff Folla WF Note: Updated sun alert to resolved per James Macfarlane. The request to update this document was sent back in March and I thought I addressed the issue. I noticed the sun alert had not been updated and made the changes today. WF State: Issued, 03-Apr-2003, Karen Edwards WF Note: oked by Joe WF State: Draft, 03-Apr-2003, Karen Edwards WF Note: i removed the paragraph that mentions FCO - sending for signoff WF State: Draft, 02-Apr-2003, Jeff Folla WF Note: Sending document to sunalert_review WF State: Draft, 02-Apr-2003, Jeff Folla WF Note: Received answers to my questions from engineer. Updated document accordingly. WF State: Draft, 01-Apr-2003, Jeff Folla WF Note: Sent SA to engineer with questions. WF State: Draft, 01-Apr-2003, Jeff Folla WF Note: Article created. Exported from KMS Creator Sat May 21 08:57:26 2005 GMT, olaf.reineke@sun.com Internal SA-FAB Eng Submission Dual-Bus Sun StorEdge 3310 JBOD Configurations May Lose SCSI Termination in a Multi-Initiator Environment Product_uuid 3db30178-43d7-4d85-8bbe-551c33040f0d|Sun StorageTek 3310 SCSI Array Attachments This solution has no attachment |
||||||||||||
|