Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000513.1 : Adding New Disk Drives to StorEdge A1000 or A3X00 Could Cause RAID Manager to Become Unavailable
PreviouslyPublishedAs 200656 Bug Id none Date of Workaround Release 20-DEC-2001 Date of Resolved Release 22-JAN-2003 Impact Increasing the capacity to a StorEdge A1000 or A3X00 array by adding new disk drives might result in RAID Manager (RM) 6.x tools and utilities being unable to access the array with the only resolution to reboot the host system. Also, an LUN that was created on the new drive(s) may disappear when the host system is rebooted or the array is reset. In this case, the LUN may not be recoverable. The data on that LUN may be lost.
Contributing Factors This issue can occur on the following releases:
This issue can occur on the following platforms:
Symptoms When a new disk or group of disks is added to an A1000 or A3X00 array and during the subsequent attempt to create an LUN or LUNs on the new disks, the RM6 tool or utility might hang and there is no longer any access to the array from RM6. Another possibility is if new LUNs are created for the new disks, on the subsequent reboot of the host system or reset of the array those new LUNs may disappear with no error messages or indications.
Workaround In the case where the RM6 tools and utilities fail to work after an LUN creation attempt was made to the new drives, the only recovery action would be to reboot the host system. In the case where an LUN was created and suddenly disappears after a reboot or array reset, then recovery of the LUN would require contacting your local Sun Enterprise Service representative. The LUN and recovery of the data may not be possible. Below is the proper procedure that must be utilized when adding new drives to an A1000 and A3X00 array. Adding Disk Drives to Existing Arrays You can add new drives to empty slots in your existing array. To add new disk drives: 1. Insert a disk drive into the tray. 2. Allow time for the drive to spin up (approximately 30 seconds). 3. Run a health check to insure that the drive is not defective. 4. Fail the drive then revive the drive to update DacStore on the drive. 5. Repeat steps 1 through 4 until all drives have been added. 6. New drives are now ready for LUN creation.
Resolution The workaround provided above is the resolution to this issue.
Modification History Date: 22-JAN-2003
Product Sun StorEdge A1000 Array Previously Published As 100968 Internal Comments
Notes from Responsible Engineer: don.curren@sun.com: I have not been able to find any manual entry that explains the process of > 2) This product has been out for almost 3 years. Why is this problem
Internal Contributor/submitter Younan.Sarkis@sun.com Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer don.curren@sun.com Internal Services Knowledge Engineer karen.edwards@central.sun.com Internal Escalation ID 531993, 532241 Internal Sun Alert Kasp Legacy ID 100968, 42066 (Sun Alert) Internal Sun Alert & FAB Admin Info Critical Category: Data Loss, Availability ==> Pervasive Significant Change Date: 2001-12-20, 2003-01-22 Avoidance: Workaround Responsible Manager: steven.kent@sun.com Original Admin Info: This document has been imported from KMS Creator and may need adjustment before re-publishing. This imported document has been reviewed/adjusted by: Review Name: Review Date: The following field(s) have been migrated with dummy values and need adjustment: Original Product: RAID Manager Migrated Product: SunTea v3.55 (Dummy) Original KMS Creator attributes below: --- PLEASE DO NOT MAKE ANY CHANGES BELOW THIS LINE! --- Sun Alert ID: 42066 Synopsis: Adding New Disk Drives to StorEdge A1000 or A3X00 Could Cause RAID Manager to Become Unavailable Category: Data Loss, Availability Product: RAID Manager BugIDs: none Avoidance: Workaround State: Resolved Date Released: 20-Dec-2001, 22-Jan-2003 Date Closed: 22-Jan-2003 Date Modified: 22-Jan-2003 Escalation IDs: 531993, 532241 Pending Patches: Resolution Patches: none FIN: I0782-1 FCO: Date Submitted: 18-Dec-2001 Submitter: Younan.Sarkis@sun.com Responsible Engineer: don.curren@sun.com Responsible Manager: steven.kent@sun.com CTE group: CPRE NWS US Responsible Writer: karen.edwards@central.sun.com Distribution: Public SunSolve Workflow History: WF State: Issued, 22-Jan-2003, Karen Edwards WF Note: Resolved WF State: Issued, 16-Jan-2002, Karen Edwards WF Note: ok for contract sunsolve WF State: Issued, 20-Dec-2001, Karen Edwards WF Note: oked per amrit WF State: Draft, 20-Dec-2001, Karen Edwards WF Note: sending to sfa-signoff WF State: Draft, 19-Dec-2001, Karen Edwards WF Note: sending to sunalert_review WF State: Draft, 18-Dec-2001, Karen Edwards WF Note: this needs substantial re-write/clarifications WF State: Draft, 18-Dec-2001, Karen Edwards WF Note: Article created. Exported from KMS Creator Sat May 21 08:46:46 2005 GMT, olaf.reineke@sun.com Internal SA-FAB Eng Submission Adding New Disk Drives to StorEdge A1000 or A3X00 Could Cause RAID Manager to Become Unavailable Attachments This solution has no attachment |
||||||||||||
|