Solution Type  Sun Alert Sure

Solution  1000513.1 :   Adding New Disk Drives to StorEdge A1000 or A3X00 Could Cause RAID Manager to Become Unavailable  


Related Items
  • Sun Storage A1000 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
200656


Bug Id
none

Date of Workaround Release
20-DEC-2001

Date of Resolved Release
22-JAN-2003

Impact

Increasing the capacity to a StorEdge A1000 or A3X00 array by adding new disk drives might result in RAID Manager (RM) 6.x tools and utilities being unable to access the array with the only resolution to reboot the host system. Also, an LUN that was created on the new drive(s) may disappear when the host system is rebooted or the array is reset. In this case, the LUN may not be recoverable. The data on that LUN may be lost.


Contributing Factors

This issue can occur on the following releases:

  • RAID Manager 6.x and earlier

This issue can occur on the following platforms:

  • StorEdge A1000
  • StorEdge A3X00


Symptoms

When a new disk or group of disks is added to an A1000 or A3X00 array and during the subsequent attempt to create an LUN or LUNs on the new disks, the RM6 tool or utility might hang and there is no longer any access to the array from RM6. Another possibility is if new LUNs are created for the new disks, on the subsequent reboot of the host system or reset of the array those new LUNs may disappear with no error messages or indications.


Workaround

In the case where the RM6 tools and utilities fail to work after an LUN creation attempt was made to the new drives, the only recovery action would be to reboot the host system. In the case where an LUN was created and suddenly disappears after a reboot or array reset, then recovery of the LUN would require contacting your local Sun Enterprise Service representative. The LUN and recovery of the data may not be possible.

Below is the proper procedure that must be utilized when adding new drives to an A1000 and A3X00 array.

Adding Disk Drives to Existing Arrays

You can add new drives to empty slots in your existing array. To add new disk drives:

1. Insert a disk drive into the tray.

2. Allow time for the drive to spin up (approximately 30 seconds).

3. Run a health check to insure that the drive is not defective.

4. Fail the drive then revive the drive to update DacStore on the drive.

5. Repeat steps 1 through 4 until all drives have been added.

6. New drives are now ready for LUN creation.


Resolution

The workaround provided above is the resolution to this issue.



Modification History
Date: 22-JAN-2003
  • State Resolved (and Closed)
  • Updated Resolution section




Product
Sun StorEdge A1000 Array

Previously Published As
100968
Internal Comments



Please see FIN I0782-1 for more information


Notes from Responsible Engineer: don.curren@sun.com:

I have not been able to find any manual entry that explains the process of
adding new drives to an array. The only place where it is documented that I can find is in
the Somona best practice guide which is only for Sun internal use only. This
process up until this point is only documented in the Somona best practice guide.
The same process that has been defined in the Somona best practice guide
section 2.3 "Adding Disks or Disk Trays" for adding new disk(s) to an A3x00
has been found to apply also to the A1000 array.

> 2) This product has been out for almost 3 years.  Why is this problem
> just surfacing now?
>

This has been a problem in the past mainly with the A3x00 array which is why the
process was included in the Sonoma best practice guide. However up until
recently
this guide was tagged for the A3x00 product only and did not include the A1000
and this information does not get to customers.




Internal Contributor/submitter
Younan.Sarkis@sun.com

Internal Eng Business Unit Group
NWS (Network Storage)

Internal Eng Responsible Engineer
don.curren@sun.com

Internal Services Knowledge Engineer
karen.edwards@central.sun.com

Internal Escalation ID
531993, 532241

Internal Sun Alert Kasp Legacy ID
100968, 42066 (Sun Alert)

Internal Sun Alert & FAB Admin Info
Critical Category: Data Loss, Availability ==> Pervasive
Significant Change Date: 2001-12-20, 2003-01-22
Avoidance: Workaround
Responsible Manager: steven.kent@sun.com
Original Admin Info: This document has been imported from KMS Creator and may need adjustment before re-publishing.

This imported document has been reviewed/adjusted by:
Review Name:
Review Date:

The following field(s) have been migrated with dummy values and need adjustment:
Original Product: RAID Manager
Migrated Product: SunTea v3.55 (Dummy)

Original KMS Creator attributes below:

--- PLEASE DO NOT MAKE ANY CHANGES BELOW THIS LINE! ---

Sun Alert ID: 42066
Synopsis: Adding New Disk Drives to StorEdge A1000 or A3X00 Could Cause RAID Manager to Become Unavailable
Category: Data Loss, Availability
Product: RAID Manager
BugIDs: none
Avoidance: Workaround
State: Resolved
Date Released: 20-Dec-2001, 22-Jan-2003
Date Closed: 22-Jan-2003
Date Modified: 22-Jan-2003
Escalation IDs: 531993, 532241
Pending Patches:
Resolution Patches: none
FIN: I0782-1
FCO:
Date Submitted: 18-Dec-2001
Submitter: Younan.Sarkis@sun.com
Responsible Engineer: don.curren@sun.com
Responsible Manager: steven.kent@sun.com
CTE group: CPRE NWS US
Responsible Writer: karen.edwards@central.sun.com
Distribution: Public SunSolve

Workflow History:

WF State: Issued, 22-Jan-2003, Karen Edwards
WF Note: Resolved

WF State: Issued, 16-Jan-2002, Karen Edwards
WF Note: ok for contract sunsolve

WF State: Issued, 20-Dec-2001, Karen Edwards
WF Note: oked per amrit

WF State: Draft, 20-Dec-2001, Karen Edwards
WF Note: sending to sfa-signoff

WF State: Draft, 19-Dec-2001, Karen Edwards
WF Note: sending to sunalert_review

WF State: Draft, 18-Dec-2001, Karen Edwards
WF Note: this needs substantial re-write/clarifications

WF State: Draft, 18-Dec-2001, Karen Edwards
WF Note: Article created.

Exported from KMS Creator Sat May 21 08:46:46 2005 GMT, olaf.reineke@sun.com
Internal SA-FAB Eng Submission
Adding New Disk Drives to StorEdge A1000 or A3X00 Could Cause RAID Manager to Become Unavailable


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback