Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1000556.1
Update Date:2011-03-01
Keywords:

Solution Type  Sun Alert Sure

Solution  1000556.1 :   Insertion or Removal of a RAID Controller on Sun StorEdge 5310 or 6130 Array May Cause the Alternate Controller to Reboot  


Related Items
  • Sun Storage 5310 NAS Appliance
  •  
  • Sun Storage 6130 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
200702


Product
Sun StorageTek 5310 NAS Appliance
Sun StorageTek 6130 Array

Bug Id
<SUNBUG: 6254438>

Date of Resolved Release
11-MAY-2007

Impact

Insertion or removal of a RAID controller as part of routine maintenance activity on Sun StorEdgeTek 5310 or 6130 arrays may cause the alternate controller in the same tray to boot, causing a complete loss of access to the array until the alternate boots up.


Contributing Factors

This issue can occur on the following platforms:

  • Sun StorEdgeTek 6130 without firmware 6.12.03.12
  • Sun StorEdgeTek 5310 without patch 119351-04

To determine the version of firmware on the system, the sscs(1M) command can be run as in the following example:

    # /opt/se6x20/cli/bin/sscs list array <array name>
    Array: <array name>
    Array Type:                6130
    Serial Number:             SUN.54062390150.0440AWF007
    Firmware Version:          06.19.23.10

    ...


Symptoms

This issue presents itself during ordinary replacement of a controller or during the replacement of a cache battery during normal maintenance.

Data hosts using the impacted arrays will see evidence of a loss of access in the host messages file. The messages vary from platform to platform, but will indicate:

  • SCSI retries
  • Fibre Channel resets
  • Devices disappearing from the Fibre Channel switch fabric

Management hosts attempting get status information from the array may get a communication error. Communications errors may present themselves during any activity. These lapses in managing the array are brief(up to 2 minutes), as the booting controller will allow management access as it finishes booting.

For 5310 and 5320 NAS Appliances, users will be unable to access shares or NFS export filesystems.


Workaround

To avoid this issue (for systems without the current firmware), it is recommended that any activity requiring maintenance of the array controller or array controller cache battery be considered an offline operation. As such, these types of maintenance activities should be performed during an outage of all data services provided by the array.


Resolution

This issue is addressed on the following platforms:

  • Sun StorEdgeTek 6130 with firmware 6.12.03.12 or later
  • Sun StorEdgeTek 5310 with patch 119351-04 or later

Note: The above firmware revision is bundled with Sun StorEdge 6130 Array Configuration Services 1.2 or later software. It is recommended that customers upgrade the management host to Common Array Manager (CAM) 5.1 or later, along with the firmware bundled within it (6.19.25.10).

Common Array Manager (CAM) 5.1 is available for download at

http://www.sun.com/download/products.xml?id=45d3689d



References

<SUNPATCH: 119351-04>

Previously Published As
102912
Internal Comments


Internal Contributor/submitter
curtis.decotis@sun.com

Internal Eng Business Unit Group
NWS (Network Storage)

Internal Eng Responsible Engineer
brian.hanvey@sun.com

Internal Services Knowledge Engineer
david.mariotto@sun.com

Internal Escalation ID
22202968, 43782256

Internal Resolution Patches
119351-04

Internal Sun Alert Kasp Legacy ID
102912

Internal Sun Alert & FAB Admin Info
Critical Category: Availability ==> HA-Failure
Significant Change Date: 2007-05-11
Avoidance: Patch
Responsible Manager: mark.briel@sun.com
Original Admin Info: [WF 11-May-2007, dave m: review completed, release]
[WF 10-May-2007, dave m: sending for review]
[WF 10-May-2007, dave m: draft created]

Product_uuid
63654ce5-f88d-11d8-ab63-080020a9ed93|Sun StorageTek 5310 NAS Appliance
8252cb91-d771-11d8-ab52-080020a9ed93|Sun StorageTek 6130 Array

References

SUNPATCH:119351-04

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.