Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000651.1 : Sun StorageTek 6130/6140/6540 and Sun StorageTek Flexline 240/280/380 Arrays May Experience Loss of Network Access From Management Host
PreviouslyPublishedAs 200861 Product Sun StorageTek Flexline 380 Array Sun StorageTek Flexline 240 Array Sun StorageTek Flexline 280 Array Sun StorageTek 6130 Array Sun StorageTek 6140 Array Sun StorageTek 6540 Array Bug Id <SUNBUG: 6583779> Date of Workaround Release 04-SEP-2007 Date of Resolved Release 18-OCT-2007 Impact Sun StorageTek 6130/6140/6540 and Sun StorageTek Flexline 240/280/380 arrays using either Common Array Manager (CAM) or SANtricity, may experience loss of network access from Management Host. Once the array network connection stops working, it is no longer possible for the Management Host to monitor or manage the array. Access to data is not affected even if the Management Host is also a Data Host. Contributing Factors This issue can occur on the following platforms:
with repeated gathering of supportData in Common Array Manager (CAM) or supportdata in SANtricity. Symptoms If the described issue occurs, from CAM's Browser User Interface Storage System Summary page, the Health of the array will say "Lost Communication" and it will not be possible to manage or monitor the array. In SANtriicty, you will be unable to connect. Attempts to ping either array controller will be unsuccessful. Attempts to use the Serial Service Interface appear to be unaffected. Workaround For immediate relief from this issue, power cycle the array. If running any monitoring scripts in addition to the services offered by CAM or SANtricity that specifically call out the collection of the array supportData (see below), stop using them until a final resolution can be provided: CAM - <fms_home>/bin/supportData -d <arrayname> -p <directory> -o <file_name> Solaris - fms_home = /opt/SUNWsefms Linux - fms_home = /opt/sun/cam/private/fms Windows - fms_home = C:\Program Files\Sun_Microsystems\StorageTek_Mgmt\Component\fms SANtricity - <SMcli_home>\SMcli -n <arrayname> -c "save storageArray supportData file=\"supportdata.zip\";" Windows - SMcli_home = C:\Program Files\StorageManager\client Solaris/Linux - SMcli_home = /opt/SM9/client A binary fix is available through normal support channels. Resolution This issue is addressed in the following releases:
The firmware versions listed above are provided as part of the Sun StorageTek Common Array Manager 6.0 release bundle. Modification History Date: 18-OCT-2007
Previously Published As 103059 Internal Comments This issue can be verified by running "inetstatShow" from the debug port. In the output you should see a "LISTEN" state on TCP Proto for port 2463 in order for CAM or SANtricity to manage the array. If this port is not listening, you have encountered the issue.
For CAM users, you will not be able to load the 6.19.25.14 firmware using the BUI, you will have to use "/opt/SUNWstksm/bin/csmservice" with the "-s" option. For SANtricity users, there is no need to reload the NVSRAM file, only the 6.19.25.24 firmware. Until the next version of CAM/SANtricity is released with this firmware, open a task to PTS to obtain it. Internal Contributor/submitter Bob.Deguc@Sun.COM Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer Brian.Hanvey@Sun.COM Internal Services Knowledge Engineer jeff.folla@sun.com Internal Escalation ID 11059810, 65566078, 37850635, 37841306, 65548488 Internal Sun Alert Kasp Legacy ID 103059 Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Pervasive Significant Change Date: 2007-09-04, 2007-10-18 Avoidance: Upgrade, Workaround Responsible Manager: Mark.Briel@Sun.COM Original Admin Info: [WF 18-Oct-2007, Jeff Folla: This is now resolved. Sent for re-release.] [WF 04-Sep-2007, Jeff Folla: Sent for release.] [WF 31-Aug-2007, Jeff Folla: Sent for review.] Product_uuid 133a82c0-478b-11dc-9b8e-080020a9ed93|Sun StorageTek Flexline 380 Array 1fa39e9c-cff3-11da-a933-080020a9ed93|Sun StorageTek Flexline 240 Array 465d2e5d-41ff-11dc-9b8e-080020a9ed93|Sun StorageTek Flexline 280 Array 8252cb91-d771-11d8-ab52-080020a9ed93|Sun StorageTek 6130 Array 8ac7dca5-a8bd-11da-85b4-080020a9ed93|Sun StorageTek 6140 Array e35cfcfc-a31a-11da-85b4-080020a9ed93|Sun StorageTek 6540 Array Attachments This solution has no attachment |
||||||||||||
|