Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1017421.1 : Using Certain sccli(1M) Commands to Manage a Sun StorEdge 3510 or 3511 Fiber Channel Array May Cause the Controller to Hang
PreviouslyPublishedAs 228517 Product Sun StorageTek 3510 FC Array Sun StorageTek 3511 SATA Array Bug Id <SUNBUG: 5039653>, <SUNBUG: 5039690> Date of Workaround Release 20-JUL-2004 Date of Resolved Release 24-AUG-2005 Impact Using certain sccli(1M) commands to manage a Sun StorEdge 3510 or 3511 Fiber Channel Array that is configured with more than 16 LUN masks (or filters) per LUN, may cause the controller to hang. As a result, the host (system) could experience a loss of access to the Sun StorEdge 3510 or 3511 LUNs. Contributing Factors This issue can occur in the following releases: SPARC Platform
The described issue only occurs if both of the following are true: 1. More than 16 LUN masks (or filters) are created per LUN. 2. The "sccli show configuration" or the "sccli show lun-maps" commands are used with sccli(1M) version 1.5, 1.6, or 1.6.1 to manage a Sun StorEdge 3510 and 3511 Fiber Channel Array. To determine the version of sccli(1M), run the following command: # sccli -v sccli version 1.5 Note: If more than 16 LUN masks (or filters) are used per LUN, StorADE should not be used. Symptoms Should the described issue occur, the "show configuration" and "show lun-maps" commands will cause the the Primary Controller to hang. There are no error messages available that would indicate the described issue has occurred. Workaround To work around the described issue, do not configure a Sun StorEdge 3510 or 3511 FC Array with more than 16 LUN masks (or filters) per LUN. If more than 16 LUN masks (or filters) are created per LUN, do not use the following sccli(1M) commands to manage a Sun StorEdge 3510 or 3511 Fiber Channel Array:
Resolution This issue is addressed in the following releases:
Modification History Date: 10-AUG-2004
Date: 24-AUG-2005
References<SUNPATCH: 113723-10><SUNPATCH: 113724-04> Previously Published As 101535 Internal Comments
Internal Contributor/submitter dave.bruce@sun.com Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer neill.wood@sun.com Internal Services Knowledge Engineer jeff.folla@sun.com Internal Escalation ID 1-1563322 Internal Resolution Patches 113723-10, 113724-04 Internal Sun Alert Kasp Legacy ID 101535, 57604 (Sun Alert) Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Pervasive Significant Change Date: 2004-07-20, 2005-08-24 Avoidance: Patch, Workaround Responsible Manager: Veerappan.Nachiappan@Sun.COM Original Admin Info: [WF 24-Aug-2005, Jeff Folla: Updated with available patches. This is now resolved.] This document has been imported from KMS Creator and may need adjustment before re-publishing. This imported document has been reviewed/adjusted by: Review Name: Review Date: Original KMS Creator attributes below: --- PLEASE DO NOT MAKE ANY CHANGES BELOW THIS LINE! --- Sun Alert ID: 57604 Synopsis: Using Certain sccli(1M) Commands to Manage a Sun StorEdge 3510 or 3511 Fiber Channel Array May Cause the Controller to Hang Category: Availability Product: Sun StorEdge 3510 FC Array, Sun StorEdge 3511 FC Array BugIDs: 5039653, 5039690 Avoidance: Workaround State: Committed Date Released: 20-Jul-2004 Date Closed: Date Modified: 10-Aug-2004 Escalation IDs: 1-1563322 Pending Patches: Resolution Patches: FIN: FCO: Date Submitted: 15-Jul-2004 Submitter: dave.bruce@sun.com Responsible Engineer: neill.wood@sun.com Responsible Manager: Veerappan.Nachiappan@Sun.COM CTE group: PTS NWS US Responsible Writer: jeff.folla@sun.com Distribution: Contract SunSolve Workflow History: WF State: Issued, 10-Aug-2004, Jeff Folla WF Note: Updated sun alert with reference to 3511 array WF State: Rework, 10-Aug-2004, Jeff Folla WF Note: Updating sun alert with reference to 3511 array WF State: Issued, 20-Jul-2004, Jeff Folla WF Note: Signoff approved by Dave Bruce. Sent for release. WF State: Draft, 20-Jul-2004, Jeff Folla WF Note: Sent for signoff. WF State: Draft, 19-Jul-2004, Jeff Folla WF Note: Sent for review. WF State: Draft, 15-Jul-2004, Jeff Folla WF Note: Article created. Exported from KMS Creator Sat May 21 09:11:48 2005 GMT, olaf.reineke@sun.com Internal SA-FAB Eng Submission Using Certain sccli(1M) Commands to Manage a Sun StorEdge 3510 or 3511 Fiber Channel Array May Cause the Controller to Hang Product_uuid 58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array 9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array ReferencesSUNPATCH:113723-10SUNPATCH:113724-04 Attachments This solution has no attachment |
||||||||||||
|