Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1019331.1
Update Date:2011-02-17
Keywords:

Solution Type  Sun Alert Sure

Solution  1019331.1 :   Controller Firmware for SE6130, ST6140 and ST6540 on Solaris may not Failover Array LUNs  


Related Items
  • Sun Storage 6540 Array
  •  
  • Sun Storage 6130 Array
  •  
  • Sun Storage 6140 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
238545


Bug Id
<SUNBUG: 6585914>

Date of Resolved Release
06-Jun-2008

Controller Firmware for SE6130, ST6140 and ST6540 on Solaris may not Failover Array LUNs (see below for details)

1. Impact

In the event of a controller RPA Memory Fault, the array controllers do not log out 
of their Fibre Channel Storage Area Networks(SAN) as expected.

This prevents the scsi_vhci driver from issuing a failover request and
allows continuous I/O retrys instead of failing them.

2. Contributing Factors

This issue may occur in the following releases:
  • Sun StorEdge 6130 Array (on Solaris) without array firmware 06.19.25.16
  • Sun StorageTek 6140 Array (on Solaris) without array firmware 06.19.25.16
  • Sun StorageTek 6540 Array (on Solaris) without array firmware 06.19.25.16

3. Symptoms

This is an example of an RPA Memory Fault:

Event Type : 6540.ProblemEvent.REC_RPA_ERR_CTL
Severity : 0

---- Sample Description ----
An RPA memory parity error was detected on controller {0}

---- Probable Cause ----
An RPA memory error has been reported on a controller.

---- Recommended Action ----
Replace the controller.


As a result the Array controller will get held in reset, with
the controller tray ID showing "88". The array logs will start
to fill up with target resets.

Date/Time: Thu May 22 20:44:02 MSD 2008
Sequence number: 10330
Event type: 1202
Event category: Error
Priority: Informational
Description: Fibre channel - TGT reset received
Event specific codes: 0/0/0
Component type: Controller
Component location: Controller in slot B
Logged by: Controller in slot B

The target resets are the result of the "Retryable" errors from the host(s).
The Solaris /var/adm/messges will fill up with messages similar to:

May 22 20:02:33 myhost scsi: [ID 107833 kern.warning] WARNING:
/scsi_vhci/ssd@g600a0b80001111110000121212121212 (ssd54):
May 22 20:02:33 myhost Error for Command: read(10)
Error Level: Retryable
May 22 20:02:33 myhost scsi: [ID 107833 kern.notice] Requested
Block: 113135664 Error Block: 113135664
May 22 20:02:33 myhost scsi: [ID 107833 kern.notice] Vendor:
STK Serial Number:
May 22 20:02:33 myhost scsi: [ID 107833 kern.notice] Sense Key:
Not Ready
May 22 20:02:33 myhost scsi: [ID 107833 kern.notice] ASC: 0x4
(<vendor unique code 0x4>), ASCQ: 0x1, FRU: 0x0

And will lack the "initiating failover" messages typical to controller array
faults as expected.

4. Workaround

The only workaround is to remove the array connection to the SAN for the
faulted controller, or to offline those ports connected to the faulted
controller by using a switch management interface for the SAN.

5. Resolution

This issue is addressed in the following releases:
  • Sun StorEdge 6130 Array (on Solaris) with firmware 06.19.25.16 or later
  • Sun StorageTek 6140 Array (on Solaris) with firmware 06.19.25.16 or later
  • Sun StorageTek 6540 Array (on Solaris) with firmware 06.19.25.16 or later
The above firmware is provided by Common Array Manager 6.0.0 or later
releases available at:

http://www.sun.com/download/index.jsp?tab=2


and specifically:

http://www.sun.com/download/products.xml?id=470d094a



This Sun Alert notification is being provided to you on an "AS IS" basis. This Sun Alert notification may contain information provided by third parties. The issues described in this Sun Alert notification may or may not impact your system(s). Sun makes no representations, warranties, or guarantees as to the information contained herein. ANY AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This Sun Alert notification contains Sun proprietary and confidential information. It is being provided to you pursuant to the provisions of your agreement to purchase services from Sun, or, if you do not have such an agreement, the Sun.com Terms of Use. This Sun Alert notification may only be used for the purposes contemplated by these agreements.

Copyright 2000-2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A. All rights reserved.

Product
Sun StorageTek 6130 Array
Sun StorageTek 6140 Array
Sun StorageTek 6540 Array

Internal Services Knowledge Engineer
karen.edwards@sun.com

Internal Contributor/submitter
curtis.decotis@sun.com

Internal Eng Responsible Engineer
rich.floyd@sun.com

Internal Eng Business Unit Group
NWS (Network Storage)

Internal Escalation ID
38086542, 37902022, 37913395, 1-22284687

Internal Sun Alert & FAB Admin Info
WF 05-jun-2008, karen: submitted a couple of days ago, i rewrote, has been ok'ed by Curtis.Decotis@Sun.COM and will send to 24hr review today
WF 06-Jun-2008, karen: released

Internal Comments
Please send technical questions to the following email: