Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1020178.1 : Sun System Firmware Patch 139442-01 (WITHDRAWN) Leaves Sun Netra T5220 Platform Unable to Power On Host After a Power Cycle
PreviouslyPublishedAs 253668 Bug Id <SUNBUG: 6797107> Product Sun Netra T5220 Server Date of Resolved Release 27-Feb-2009 Sun System Firmware Patch 139442-01 (WITHDRAWN) Leaves Sun Netra T5220 Platform Unable to Power On Host After a Power Cycle 1. Impact Upgrading the Sun System Firmware to version 7.2.0 using patch 139442-01 on a Sun Netra T5220 Server may cause host power-on failure. This happens only if the power has been disconnected from the system since the firmware upgrade. When this occurs, the system will power on and will immediately be powered off by the Service Processsor (SP) due to environmental faults. The above mentioned patch has been withdrawn and is no longer available on SunSolve. 2. Contributing Factors This issue can occur on the following platform: SPARC Platform:
1. The x86 platform is not affected by this issue. No other Sun systems are affected by this issue. 2. Sun Netra T5220 Server with Sun System Firmware version 7.1.x is not impacted by this issue. 3. This issue will occur only if the system power is disconnected anytime after the Sun System Firmware upgrade to 7.2.0. To determine the firmware version on the system, log in to the service processor and run the 'showhost' command as in the following example: sc> showhost 3. Symptoms Soon after the 'poweron' command is issued to the Service Processor, messages similar to the following may return on the console and the host will be powered off: Fault | critical: SP detected fault at time Tue Jan 20 14:22:47 2009. V_VDDIO at /SYS/MB 4. Workaround To avoid this issue, do not install the firmware delivered in 139442-01. If 139442-01 firmware has already been installed, replace it with the corrected firmware as described below. 5. Resolution This issue is addressed on the following platform: SPARC Platform
Copyright 2000-2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A. All rights reserved. References<SUNPATCH: 139442-02>Internal Comments Please send technical questions to the following email: sunalert-tech-questions@sun.com and CC the following persons: Internal Contributor/Submitter Internal Eng Responsible Engineer Internal Services Knowledge Engineer This regression is introduced when Netra T5220 ILOM fw is updated to use new ipmi infrastructure. This regression introduced by putback for BugID 6767014 Turgo: Netra T5220 needs to move to ipmi redesign Internal Contributor/submitter Christopher.Boland@Sun.COM Internal Eng Responsible Engineer ravikishore.chadalawada@sun.com Internal Services Knowledge Engineer david.mariotto@sun.com Internal Eng Business Unit Group Systems Group - Netra Systems and Networking Internal Escalation ID 1-25459891, 70596540 Internal Resolution Patches 139442-02 Internal Sun Alert & FAB Admin Info 26-Feb-2009, david m: draft created, send for 24hr review 29-Feb-2009, david m: review OK, send to release ReferencesSUNPATCH:139442-02Attachments This solution has no attachment |
||||||||||||
|