Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1020437.1 : Some Sun Fire, SPARC Enterprise, and Sun Storage Systems Using Power Supply Units Within a Certain Date Code Range May Experience a Thermal Event Upon PSU Failure
PreviouslyPublishedAs 258408 Bug Id N/A Product Sun Fire X4240 Server Sun Fire X4250 Server Sun Fire X4440 Server Sun Fire X4450 Server Sun SPARC Enterprise T5240 Server Sun SPARC Enterprise T5220 Server Sun Storage 7110 Unified Storage System Sun Storage 7410 Unified Storage System Date of Preliminary Release 05-May-2009 Date of Resolved Release 23-Jul-2009 Some Sun Fire, SPARC Enterprise, and Sun Storage Systems Using Power Supply Units Within a Certain Date Code Range May Experience a Thermal Event Upon PSU Failure 1. Impact Power supplies within a certain Date Code range for some Sun Fire, SPARC Enterprise, and Sun Storage systems (as listed below) may be vulnerable to a thermal event upon PSU failure. 2. Contributing Factors This issue can occur on the following platforms:
300-1897-04 (A217), date codes 0827 and
0828
Affected Power Supply Unit (PSU) Sun part numbers for Sun Fire X4240, X4250, X4440, X4450 Servers and Sun SPARC Enterprise T5220/T5240 Servers are: 300-2138-03 (A235), date code 0828 To determine the Date Code for the SPARC Enterprise T5220/T5240 Servers, a physical inspection of the PSU will be necessary. Since the PSUs in SPARC Enterprise T5220/T5240 Servers are N+1 redundant and hot-swappable, they can be removed one PSU at a time for visual inspection of the Serial Number bar code label on the PSU. Sun bar code label example: 19080DR-0828A70ADR
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | \ \ \ \ \ \ | | | | | | | | | | | \ \ \ \ \ \ Vendor \ \ \ \ \ \ \ \ \ \ ----- unique serial number identifier Serial# \ \ \ \ Date \ \ \ \ ---- date code: 0828 = year 2008, week 28 Above example PSU serial number: 19080DR-0828A70ADR represents date code 0828 To determine the power supply part number and date code for the Sun Fire systems listed above, use ipmitool(1m) 1.8.9.4 or later (available on the Sun "Tools and Drivers" CD): ipmitool
-H <ILOM IP> -U root fru
FRU Device Description : ps0.fru (ID 31) Board Mfg : POWER ONE Board Product : A217 Board Serial : 19080DR-0828A70ADR <-- Affected date code: 0827 & 0828 = year 2008, week 27 and week 28 Board Part Number : 300-1897-04 The "Tools and Drivers" CD can be downloaded at http://www.sun.com/download/index.jsp?tab=2 under the appropriate product listing. Note for the Sun Fire X4450: The system must have been upgraded from ELOM to ILOM in order to see the PSU info via ipmitool. Instructions for upgrading can be found in The ELOM-to-ILOM Migration Users Guide at http://docs.sun.com/source/820-4930-12/To determine the power supply part number and date code for the Sun Storage 7110/7410, connect to the Service Processor via ssh(1). Log in as root/appliance password, then enter "show /SYS/PS0" (or "show /SYS/PS1"). This will return the PSU information including the Serial Number and Date Code, as in the following example: login: root3. Symptoms The system will lose power from the affected PSU (with subsequent loss of power redundancy if other PSU(s) are already offline). The system may shut down, and may be accompanied by a burning odor or smoke. 4. Workaround There is no workaround for this issue. Please see the Resolution section below. 5. Resolution This issue has since been corrected in the manufacturing process and is being addressed with a proactive service implementation plan. Please contact your Sun Service Representative for remediation procedures and additional details regarding this issue. . Modification History 14-May-2009: Updated Contributing Factors for clarifications 23-Jul-2009: Updated Resolution section; Issue now Resolved Internal Comments (for SAs) Customer Support: Please reference the following for complete details: FAB Solution 260490 - FCO A0306-1: Some Sun Fire, SPARC Enterprise, and Sun Storage Systems using Power Supply Units within a certain date code range may experience a Thermal Event upon PSU failure. Internal Contributor/submitter David.Swift@Sun.COM Internal Eng Responsible Engineer Mohammad.Alamdarha@sun.com Internal Services Knowledge Engineer david.mariotto@sun.com Internal Eng Business Unit Group SVS (SPARC Volume Systems, Horizontal Systems (includes T2000/Ontario), NWS (Network Storage), Systems Group-x64 (X4100-X4600 (includes M2), V20z/V40z/V60z/V65z, Ultra20/40) Internal Sun Alert & FAB Admin Info 04-May-2009, david m: draft created, sent to Legal review, send to 24hr review 05-May-2009, david m: Legal approved, 24hr review BU and Tech completed, send to publish 14-May-2009, david m: updated CF for clarifications, also Internal section info 23-Jul-2009, david m: FAB 260490/FCO A0306-1 now released, update Res, republish Resolved Attachments This solution has no attachment |
||||||||||||
|