Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1020437.1
Update Date:2010-12-09
Keywords:

Solution Type  Sun Alert Sure

Solution  1020437.1 :   Some Sun Fire, SPARC Enterprise, and Sun Storage Systems Using Power Supply Units Within a Certain Date Code Range May Experience a Thermal Event Upon PSU Failure  


Related Items
  • Sun Fire X4440 Server
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun SPARC Enterprise T5220 Server
  •  
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun Fire X4240 Server
  •  
  • Sun Fire X4450 Server
  •  
  • Sun Fire X4250 Server
  •  
  • Sun Storage 7410 Unified Storage System
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
258408


Bug Id
N/A

Product
Sun Fire X4240 Server
Sun Fire X4250 Server
Sun Fire X4440 Server
Sun Fire X4450 Server
Sun SPARC Enterprise T5240 Server
Sun SPARC Enterprise T5220 Server
Sun Storage 7110 Unified Storage System
Sun Storage 7410 Unified Storage System

Date of Preliminary Release
05-May-2009

Date of Resolved Release
23-Jul-2009

Some Sun Fire, SPARC Enterprise, and Sun Storage Systems Using Power Supply Units Within a Certain Date Code Range May Experience a Thermal Event Upon PSU Failure

1. Impact

Power supplies within a certain Date Code range for some Sun Fire, SPARC Enterprise, and Sun Storage systems (as listed below) may be vulnerable to a thermal event upon PSU failure.

2. Contributing Factors

This issue can occur on the following platforms:
  • Sun Fire X4240, X4250, X4440, X4450 Servers
  • Sun SPARC Enterprise T5220/T5240 Servers
  • Sun Storage 7110/7410
Affected Power Supply Unit (PSU) Sun part numbers for Sun Fire X4240, X4250, X4440, X4450 Servers and Sun Storage 7110/7410 are:

300-1897-04 (A217), date codes 0827 and 0828

Affected Power Supply Unit (PSU) Sun part numbers for Sun Fire X4240, X4250, X4440, X4450 Servers and Sun SPARC Enterprise T5220/T5240 Servers are:

300-2138-03 (A235), date code 0828

To determine the Date Code for the SPARC Enterprise T5220/T5240 Servers, a physical inspection of the PSU will be necessary. Since the PSUs in SPARC Enterprise T5220/T5240 Servers are N+1 redundant and hot-swappable, they can be removed one PSU at a time for visual inspection of the Serial Number bar code label on the PSU.

Sun bar code label example:

19080DR-0828A70ADR
 | | | | | | |    | | | |  | | | | | | |
 | | | | | | |    | | | |   \ \ \ \ \ \
 | | | | | | |    | | | |    \ \ \ \ \ \
Vendor      \ \ \ \     \ \ \ \ \ \  ----- unique serial number identifier
Serial#       \ \ \ \
Date            \ \ \ \   ---- date code: 0828 = year 2008, week 28

Above example PSU serial number: 19080DR-0828A70ADR represents date code 0828

To determine the power supply part number and date code for the Sun Fire systems listed above, use ipmitool(1m) 1.8.9.4 or later (available on the Sun "Tools and Drivers" CD):

ipmitool -H <ILOM IP> -U root fru
FRU Device Description : ps0.fru (ID 31)
Board Mfg               : POWER ONE
Board Product         : A217
Board Serial            : 19080DR-0828A70ADR  <-- Affected date code: 0827 & 0828 = year 2008, week 27 and week 28
Board Part Number  : 300-1897-04

The "Tools and Drivers" CD can be downloaded at http://www.sun.com/download/index.jsp?tab=2 under the appropriate product listing.

Note for the Sun Fire X4450: The system must have been upgraded from ELOM to ILOM in order to see the PSU info via ipmitool. Instructions for upgrading can be found in The ELOM-to-ILOM Migration Users Guide at
http://docs.sun.com/source/820-4930-12/
To determine the power supply part number and date code for the Sun Storage 7110/7410, connect to the Service Processor via ssh(1). Log in as root/appliance password, then enter "show /SYS/PS0" (or "show /SYS/PS1"). This will return the PSU information including the Serial Number and Date Code, as in the following example:
login: root
Using keyboard-interactive authentication.
Password:

Sun(TM) Integrated Lights Out Manager
Version 2.0.2.5
Copyright 2007 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.

-> show /SYS/PS0

/SYS/PS0
Targets:
PRSNT
VINOK
PWROK

Properties:
type = Power Supply
fru_name = A217
fru_manufacturer = POWER ONE
fru_part_number = 300-1897-04
fru_serial_number = 19080DR-0828A70ADR Affected date code: 0827 & 0828 = year 2008, week 27 and week 28
...
3. Symptoms

The system will lose power from the affected PSU (with subsequent loss of power redundancy if other PSU(s) are already offline). The system may shut down, and may be accompanied by a burning odor or smoke.

4. Workaround

There is no workaround for this issue. Please see the Resolution section below.

5. Resolution

This issue has since been corrected in the manufacturing process and is being addressed with a proactive service implementation plan. Please contact your Sun Service Representative for remediation procedures and additional details regarding this issue.

.

Modification History
14-May-2009: Updated Contributing Factors for clarifications
23-Jul-2009: Updated Resolution section; Issue now Resolved


Internal Comments (for SAs)
Customer Support:

Please reference the following for complete details:



FAB Solution 260490 - FCO A0306-1: Some Sun Fire, SPARC Enterprise, and
Sun Storage Systems using Power Supply Units within a certain date code
range may experience a Thermal Event upon PSU failure.
Internal Contributor/submitter
David.Swift@Sun.COM

Internal Eng Responsible Engineer
Mohammad.Alamdarha@sun.com

Internal Services Knowledge Engineer
david.mariotto@sun.com

Internal Eng Business Unit Group
SVS (SPARC Volume Systems, Horizontal Systems (includes T2000/Ontario), NWS (Network Storage), Systems Group-x64 (X4100-X4600 (includes M2), V20z/V40z/V60z/V65z, Ultra20/40)

Internal Sun Alert & FAB Admin Info
04-May-2009, david m: draft created, sent to Legal review, send to 24hr review
05-May-2009, david m: Legal approved, 24hr review BU and Tech completed, send to publish
14-May-2009, david m: updated CF for clarifications, also Internal section info
23-Jul-2009, david m: FAB 260490/FCO A0306-1 now released, update Res, republish Resolved


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback