Solution Type Sun Alert Sure Solution 1267797.1 : Hot-Swap of PSU on Sun Blade 6000/6048 Chassis May Cause Damage to Sun Blade X6250 Server Modules
In this Document
Applies to:Sun Blade X6250 Server Module - Version: Not ApplicableSPARC x86 _______________ _______________ Date of Resolved Release: 18-Nov-2010 ________________________________ DescriptionHot-swap of a Power Supply Unit (PSU) on the Sun Blade 6000/6048 chassis with Sun Blade X6250 server(s) present may cause motherboard damage to one or more X6250 servers simultaneously, and the blades will no longer power on. As a result, blade replacement may be required. Likelihood of OccurrenceThis issue can occur on the following platform:
Note: This issue only affects the Sun X6250 blades in the Sun Blade 6000/6048 chassis. Possible SymptomsIf a PSU in the Sun Blade 6000/6048 chassis is hot-swapped while powered on, the ECB circuit on the X6250 blade motherboard may be damaged due to a voltage spike. This will cause the blade to become unusable, and the blade will not power on. Workaround or ResolutionTo avoid occurrence of this issue, either: A) completely remove any X6250 blades from the 6000/6048 chassis before hot-swapping a PSU on the chassis or B) power down the whole chassis before replacing a PSU, even in a redundant power configuration scenario. Modification History18-Nov-2010: Released as ResolvedPlease send technical questions to the following email: sunalert-tech-questions@sun.com and copy the Responsible Engineer and the Oracle Knowledge Analyst Internal Contributor/Submitter: mick.tabor@oracle.com Internal Eng Responsible Engineer: tong-ming.zhou@oracle.com Oracle Knowledge Analyst: david.mariotto@oracle.com Internal Eng Business Unit Group: x64 Internal Escalation ID: 72488200, 72898196 ReferencesSUNBUG:6946574Attachments This solution has no attachment |
||||||||||||
|