Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1002426.1
Update Date:2011-06-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1002426.1 :   Battery Replacement Procedure for Sun StorEdge[TM] 3310SCSI/3510FC/3511FC Arrays  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3310 Array
  •  
  • Sun Storage 3511 SATA Array
  •  
  • Sun Storage 3320 SCSI Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
203394


Applies to:

Sun Storage 3310 Array
Sun Storage 3510 FC Array
Sun Storage 3511 SATA Array
Sun Storage 3320 SCSI Array - Version: Not Applicable and later    [Release: N/A and later]
All Platforms

Goal

Description


Follow the correct procedure to replace a failed/expired battery on a Sun StorEdge[TM] 3310 SCSI Array, 3320 SCSI Array, 3510 FC Array, or 3511 SATA Array.

Refer to the "Battery Fru" chapter in the FRU Replacement Guide for details.

Solution


Steps to Follow



1. Verify battery LED before proceeding with replacement.. The battery LED, located on the far right side of the
controller module,  is amber if the battery is bad or missing, blinking green if the battery is charging, and  solid green
when the battery is fully charged (as in the table below):



GREEN

BLINKING GREEN

AMBER

battery is fully charged

battery charging

battery bad or missing

2. Verify the battery status in the firmware interface as described in the "Battery Status on Initial Firmware Screen"
section in the FRU Replacement Guide.

3. In the 3510 FC or 3511 SATA array, check the status using the sccli>show battery-status cli command:

Sccli> show battery-status

Status values include:

  • Good.  

  • Expired  - Replace battery.

  • Warning - indicates that the battery will expire within 21 days; replace the battery

4. To replace the battery in a 33x0 SCSI Array, follow the FRU Replacement procedure for: "Replacing a SCSI Battery".

5. To replace the battery in a 3510 FC or 3511 SATA Array, follow the FRU Replacement procedure for: "Replacing an FC Battery".

6. For the 3510 FC or 3511 SATA array, set the in-service as described in section 4.5 FC Battery Status and In-Service Date.



Product
Sun StorageTek 3510 FC Array
Sun StorageTek 3310 SCSI Array
Sun StorageTek 3320 SCSI Array
Sun StorageTek 3511 SATA Array

3510FC, 3310SCSI, 3511FC, Storedge Array, Battery
Previously Published As
83023

Change History
Date: 2009-12-23
User Name: sue.copeland@sun.com
Action: Currency & Update

10.Check the battery status using sccli > show battery-status make sure that you see a good status on the new battery that was installed.
11.Next update the placed in service date to reset the expiration date on the new battery. sccli > show battery-status -u
This is a wrong information as for 3310, you get this error :
sccli> show battery-status
sccli: this operation is only supported on Fibre Channel primary RAID controller devices
Version: 0
Date: 2006-09-22
User Name: 84757
Action: Add Comment
Comment: Please remove from Sun StorEdge 3310 SCSI array :


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.