Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1002426.1 : Battery Replacement Procedure for Sun StorEdge[TM] 3310SCSI/3510FC/3511FC Arrays
PreviouslyPublishedAs 203394
Applies to:Sun Storage 3310 ArraySun Storage 3510 FC Array Sun Storage 3511 SATA Array Sun Storage 3320 SCSI Array - Version: Not Applicable and later [Release: N/A and later] All Platforms GoalDescriptionFollow the correct procedure to replace a failed/expired battery on a Sun StorEdge[TM] 3310 SCSI Array, 3320 SCSI Array, 3510 FC Array, or 3511 SATA Array. Refer to the "Battery Fru" chapter in the FRU Replacement Guide for details. SolutionSteps to Follow1. Verify battery LED before proceeding with replacement.. The battery LED, located on the far right side of the controller module, is amber if the battery is bad or missing, blinking green if the battery is charging, and solid green when the battery is fully charged (as in the table below):
2. Verify the battery status in the firmware interface as described in the "Battery Status on Initial Firmware Screen" 3. In the 3510 FC or 3511 SATA array, check the status using the sccli>show battery-status cli command: Sccli> show battery-status Status values include:
4. To replace the battery in a 33x0 SCSI Array, follow the FRU Replacement procedure for: "Replacing a SCSI Battery". 5. To replace the battery in a 3510 FC or 3511 SATA Array, follow the FRU Replacement procedure for: "Replacing an FC Battery". 6. For the 3510 FC or 3511 SATA array, set the in-service as described in section 4.5 FC Battery Status and In-Service Date. Product Sun StorageTek 3510 FC Array Sun StorageTek 3310 SCSI Array Sun StorageTek 3320 SCSI Array Sun StorageTek 3511 SATA Array 3510FC, 3310SCSI, 3511FC, Storedge Array, Battery Previously Published As 83023 Change History Date: 2009-12-23 User Name: sue.copeland@sun.com Action: Currency & Update 10.Check the battery status using sccli > show battery-status make sure that you see a good status on the new battery that was installed. 11.Next update the placed in service date to reset the expiration date on the new battery. sccli > show battery-status -u This is a wrong information as for 3310, you get this error : sccli> show battery-status sccli: this operation is only supported on Fibre Channel primary RAID controller devices Version: 0 Date: 2006-09-22 User Name: 84757 Action: Add Comment Comment: Please remove from Sun StorEdge 3310 SCSI array : Attachments This solution has no attachment |
||||||||||||||||
|