Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1002897.1 : SL8500 - Replacing HandBot with Service Safety Door Feature Installed
PreviouslyPublishedAs 203989 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential for Partners and Oracle Support personnel
Applies to:Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later [Release: N/A and later]All Platforms Checked for relevance on 9-Feb-2011. GoalDescriptionOracle/StorageTek[TM] SL8500 Modular Library System, Replacing HandBot with Service Safety Door Feature Installed All 8-Bot SL8500 libraries with the Service Safety Door installed via CB_102237 or FB_102235 should not perform a HandBot replacement without using the SSD. If a HandBot is replaced by opening the library front access doors without employing the SSD it will probably result in an initialization error. SolutionSteps to FollowReplacing HandBot with Service Safety Door Feature Installed All 8Bot SL8500 libraries with the Service Safety Door installed via CB_102237 or FB_102235 should not perform a HandBot replacement without using the SSD. If a HandBot is replaced by opening the library front access doors without employing the SSD it will probably result in an initialization error. If a HandBot fails to position itself in the service safety area after a failure: -Check the library event log and determine if the HandBot failed with a reach unsafe error. Note: The system is architectured not to move on the rail in the advent of a reach unsafe error. -If the error is associated with a reach unsafe error a soft reboot via the SLC diagnostic menu can be done as a last ditch effort. Note: There is some risk of the HandBot dropping the tape during recovery and the initialization should be monitored. -If there is not a reach unsafe error a soft reboot should be performed via SLC. @ SL8500 Modular Library System, Replacing HandBot with Service Safety Door Feature Installed, Modular Library System, HandBot, CRCM Previously Published As 90801 Attachments This solution has no attachment |
||||||||||||
|