Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1003250.1 : Dual hosting a Sun StorEdge[TM] A3x00 array
PreviouslyPublishedAs 204466 Steps to Follow If your customer is attempting to dual host a A3x00 array in a 1X5 configuration, the 2 controllers in the array module must be set to independent mode. You can check this by running the following command after the RAID Manager (RM6) software is installed. # storutil -c nasc_001 -d nasc_001: Controller A: 1T71525033 ( c3t5d0 ) Controller B: 1T93500060 ( c2t4d1 ) Independent Controller Configuration: OFF To make changes to this configuration you use the same command with different options. #storutil -c nasc_001 -i on storutil succeeded! Product Sun StorageTek A3500 Array Sun StorageTek A3000 Sun StorageTek A3500 FC Array Internal Comments
Previously Published As 26823 Change History Date: 2006-01-19 User Name: 31620 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT Version: 0 Date: 2006-01-19 User Name: 31620 Action: Update Started Comment: SSH AUDIT Version: 0 Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : George Bolduc comment : Looks fine. date : May 10, 2001 updated by : Tim Warembourg comment : This was written after a problem he helped me with date : May 9, 2001 updated by : Mike Young comment : No comment date : May 8, 2001 updated by : Mike Young comment : Article created. date : May 7, 2001 Version: 0 Product_uuid 2a8022d4-0a18-11d6-8043-ee5a180fdb7f|Sun StorageTek A3500 Array 2a7ca41a-0a18-11d6-82f2-e96014c515ea|Sun StorageTek A3000 b648cdf0-efb8-4d4f-93d4-b17c1baf1935|Sun StorageTek A3500 FC Array Attachments This solution has no attachment |
||||||||||||
|