Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1004261.1
Update Date:2009-11-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  1004261.1 :   Sun Fire[TM] X4600 M2 Server: Some 8xDIMM CPU Books have their DIMMs installed in incorrect location  


Related Items
  • Sun Fire X4600 M2 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>x64 Servers
  •  

PreviouslyPublishedAs
205889


Description
Disclaimer: Opening and examining cards and moving DIMMs will not void warranty when conforming with the instructions of this technical instruction.
Instead of correctly populating DIMMs in pairs starting from white DIMM slots furthermost from the CPU (DIMM 6 and 7), DIMM pairs were incorrectly populated in manufacturing starting from black DIMM slots closest to the CPU (DIMM 0 and 1).  Incorrectly populated DIMMs have not been verified to work stably by Engineering and should be avoided.


Steps to Follow
Affected part number: All x4600(M2) 8xDIMM CPU Book Configurations.
Serial Number range: Contact Sun support for more information.

Symptom:

Systems may experience intermittent power downs or panics when DIMMs are installed incorrectly.

Corrective Action:

Ensure all CPU Books have DIMMs populated in pairs starting from white DIMM pair furthermost from CPU.

Reference docs:

Sun Fire X4600 and Sun Fire X4600 M2 Servers Service Manual (819-4342) - Appendix F

  • Please check system configuration before calling support. *

Disclosure:

  • Checking the cpu cards does not invalidate your warranty *


Product
Sun Fire X4600 M2 Server

Internal Comments
Audited/updated 20/11/09 - James.Carter@Sun.COM, x64 Content Team Member

x4600, 8 dimm, reboot, intermitant, dimm, configuration
Previously Published As
91304

Change History
Date: 2007-12-03
User Name: 97961
Action: Approved
Comment: - Added disclaimer according to words in the comments area
Version: 5
Date: 2007-12-03

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback