Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1004344.1 : Validating Sun StorEdge[TM] 6920 Pool Creation
PreviouslyPublishedAs 206005 Description The purpose of this document is to provide basic steps for pool creation for the 6920 array, via the Browser User Interface(BUI) or sscs Command Line Interface(CLI). Content will be limited to a basic usage using the CLI or BUI interfaces
Steps to Follow Validating Sun StorEdge[TM] 6920 Pool Creation: A. Start By Planning Pool layout planning and considerations should be reviewed by
After answering these questions please review the contents of the 6920 Best Practices, and identify that you are prepared with at least:
If all the information above is provided, continue to Step B. B. Basic Usage Using Browser or SSCS interfaces We consider basic pool creation as creating a storage pool with NO CAPACITY. By following the instructions below, you will have created a pool without any VDisks, and will have to add capacity to it later. SSCS Pool Creation usage for sscs, can be reviewed in the SSCS Quick Reference Guide. The sscs usage for basic pool creation is as follows. create -p|--profile <string> [-S|--sdomain <string>] [-d|--description <string>] pool <string> An example: ./sscs create -p raid5-profile pool cli-pool This will create a pool named cli-pool using the parameters from the raid5-profile profile, which resides in the Storage Domain DEFAULT. NOTE1: The Storage Domain is assumed to be DEFAULT when it is not specified by the -S switch in the usage. BUI
At this point the Pop-Up window will disappear, and the main browser screen will refresh, and a success or failure message will be displayed in the Storage Pool Summary page, and the pool will be listed in this page, sorted alphanumerically.
C. Creation Failure. Please review the following list for a failure message and corresponding action. Please follow the action that describes your symptom. BUI Message: Action: Message: Action: SSCS Message: Action: Message: Action: Message: Action: Message: Action: Message: Action: If a message is not listed, or an action above did not work, go to Step D. D. Data Collection Please collect the following information:
sscs list sdomain NOTE 2: Screen captures of the summary page for each object could be used, as well, for BUI related creations. Once this information is collected, please contact Sun Support Product Sun StorageTek 6920 System Sun StorageTek 6920 Maintenance Update 2 Sun StorageTek 6920 Maintenance Update 1 Internal Comments Sun Support This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: storage-os-disk-mid-domain@sun.com The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK.
E. Validate that services are running properly on the SP
Reference document <Document: 1007129.1> Validating Services on a Sun StorEdge 6920 Service Processor
Reference document <Document: 1005447.1> Sun StorEdge[TM] 6920 Health Checklist
Provide the following:
6920, pool, creation, sscs, BUI, normalized, audited Previously Published As 90391 Change History Date: 2007-09-27 User Name: 95826 Action: Approved Comment: - verified metadata - review date ok : 2008-09-26 - checked normalized data - checked for TM - none added - checked audience : contract Publishing Version: 4 Date: 2007-09-27 User Name: 95826 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|