Asset ID: |
1-71-1005062.1 |
Update Date: | 2010-06-28 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1005062.1
:
How to use the sccli command to configure and unconfigure Global Spare Disks in Sun Storage 3310, 3320, 3510, and 3511 Arrays
Related Items |
- Sun Storage 3510 FC Array
- Sun Storage 3511 SATA Array
- Sun Storage 3310 Array
- Sun Storage 3320 SCSI Array
|
Related Categories |
- GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
|
PreviouslyPublishedAs
207118
Applies to:
Sun Storage 3310 SCSI Array
Sun Storage 3510 FC Array
Sun Storage 3511 SATA Array - Version: Not Applicable and later [Release: NA and later]
Sun Storage 3320 SCSI Array - Version: Not Applicable and later [Release: NA and later]
All Platforms
Goal
Description
This document shows the procedures to configure and unconfigure global spares using the Sun StorEdge 3000 Family CLI 2.x sccli> command.
Solution
Steps to Follow:
Use help to see the unconfigure syntax:
sccli> help unconfigure
unconfigure {local-spare|global-spare} []
unconfigure a local or global spare drive
How to unconfigure the global spare disk :
sccli> show disks
Ch Id Size Speed LD Status IDs
-----------------------------------------------------------------------
2 6 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTL4UM
2 7 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTKH6M
2 8 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CT8GWM
2 9 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CT9T5M
2 10 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTEHZM
2 11 232.88GB 200MB GLOBAL STAND-BY HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTH1DM
sccli> unconfigure global-spare 2.11
sccli> show disks
Ch Id Size Speed LD Status IDs
-----------------------------------------------------------------------
2 6 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTL4UM
2 7 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTKH6M
2 8 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CT8GWM
2 9 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CT9T5M
2 10 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTEHZM
2 11 232.88GB 200MB NONE FRMT HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTH1DM
At this point we have unconfigured the Global Spare Disk.
Steps to configure it again are:
sccli> help configure global-spare
configure global-spare
configure a disk as a global spare
sccli> configure global-spare 2.11
See the : Sun StorEdge 3000 Family CLI 2.5 User’s Guide
(817-4951)
for details.
Change History
Date: 2010-06-28
User Name: susan.copeland@oracle.com
Action: Currency and update
Attachments
This solution has no attachment