Solution Type Technical Instruction Sure Solution 1005364.1 : How to set the clock date on Sun Blade[TM] 8000 Chassis Monitoring Modules (CMM)
PreviouslyPublishedAs 207478
Applies to:Sun Blade 8000 P System - Version: Not ApplicableSun Blade 8000 System - Version: Not Applicable and later [Release: N/A and later] All Platforms GoalDescriptionDocument to check and adjust date/time on Sun Blade 8000 Chassis Management Modules (CMMs)Symptoms
Purpose/ScopeThis document gives details on how to adjust the CMM date and time. This is highly recommended to ensure log files of chassis events processes are kept in sync between Chassis CMM and blade Service Processors, to ensure easy monitoring of faults, events etcSolutionSteps to FollowHow to set date on CMM in Sun Blade[TM] 8000. 1. Confirm Active CMM time and date -> show /CMM/clock
2a. Set CMM NTP server -> set /CMM/clock usentpserver=enabled -> show /CMM/clock -> show /CMM/clients/ntp/server/1 -> set /CMM/clients/ntp/server/1 address= -> show /CMM/clients/ntp/server/1 -> set /CMM/clients/ntp/server/2 address= -> show /CMM/clients/ntp/server/2 or 2b. Set CMM local time -> set /CMM/clock datetime=MMddHHmmYYYY -> show /CMM/clock MM=month ; dd=day ; HH=hour (in 24H format) ; mm=minute ; YYYY=year NOTE: NTP is the preferred method of clock management. 3. Confirm Active CMM time and date
-> show /CMM/clock
4a. If running 1 CMM, then skip to step 5. Since the clock setting is local to the CMM, if running 2 CMM's, check which is current Active, then force a failover. -> show /CMM/redundancy fru_name
This will forcibly log out the user. Login as 'root' or an account with Administrator privilege. 4b. If using NTP method via step 2a, then this should synchronize
to the NTP server upon becoming Active, with the setting already made
on the Active.
-> show /CMM/clock
4c. If using CMM local time method via step 2b, then the new Active CMM time and date needs to be set again: -> set /CMM/clock datetime=MMddHHmmYYYY
MM=month ; dd=day ; HH=hour (in 24H format) ; mm=minute ; YYYY=year 5. Login to 'sunservice' on each CMM directly to commit the hardware clock changes. Note, you should not use the CMM HA address since each CMM maintains its own local hardware clock, and both need to be set independently. 5a. Set CMM0 Linux time and date:
# ssh -l sunservice
5b. Set CMM1 Linux time and date (using the same procedure as in 5a) # ssh -l sunservice etc 6. Verify the changes survive across CMM resets: 6a. Login as 'root' or an account with Administrator privilege to Active CMM.
# ssh -l root
NOTE: If running 2 CMM's, this will force a failover. 6b. Wait 2 minutes for this CMM to reset and boot. 6c. If running 1 CMM, then login to the CMM and verify the clock is current time:
-> show /CMM/clock
This should complete the process for a 1 CMM system. 6d. If running 2 CMM's, then login to the current Active CMM after the failover from step 6a. Reset the current Active CMM: -> show /CMM/clock
This will again force a failover. Now login to the new Active CMM that was originally reset in step 6a. and verify the time is still set current:
-> show /CMM/clock
Wait 2 minutes for the redundant CMM to reset and boot. Verify the redundant CMM is online:
-> show /CMM/redundancy status
Wait until this status shows as "Active" and not "Stand-alone". Force a failover to verify the local clock of the 2nd CMM.
-> set /CMM/redundancy initiate_failover_action=true
This will force a failover and logout the Active CMM. Now login to the new Active CMM that was reset at the beginning of this step 6d. and verify the time is still set current:
-> show /CMM/clock
This completes the process for 2 CMM systems. Internal Comments If the CMM is running ILOM 2.0.1.1 or later, then step 5 is not necessary. Step 5 is only necessary if the CMM is running ILOM 1.1.5 or earlier, due to CR 6530888. Step 6 may not be necessary in either case, but is good practice. This document contains normalized content and is managed by the the Domain Lead (s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: Domain Lead: Dencho.Kojucharov@sun.com Feedback Alias: blade_normalizers@sun.com normalized, CMM, date, NTP, clock, sb8000, 8000, blade Previously Published As 89613 Change History Date: 2008-09-29 User Name: 79977 Action: Updated Comment: Bought document under normalization project Attachments This solution has no attachment |
||||||||||||
|