DescriptionThis document describes the process for mapping between logical and physical device names on Sun[TM] 450 Systems.
Steps to FollowMapping Between Logical and Physical Device Names on Ultra 450
 Procedure for translating between the various
 logical and physical names used to identify internal disk drives in a
 Sun Ultra[Tm} 450 workstation or Ultra[TM} Enterprise 450 server
 Both the Sun Ultra 450 workstation and the Ultra Enterprise 450 server
 can accommodate up to 20 internal UltraSCSI disk drives. Each drive is
 labeled with a disk slot number between 0 and 19.
-----------------------------------------------------------------------
Configuring Disk slot Associations
The procedures assumes that the NVRAM parameter disk_led_assoc is correctly 
set to match the location of any PCI UltraSCSI controller cards that control 
the internal disk drives in your system.
In order to make this association you must follow the steps below.
1.  Power on the system.
2.  When the system banner is displayed on the monitor, immediately enter 
 the Stop-a sequence on the Sun keyboard.
3.  When the ok prompt is displayed, enter the following command:
 
 OK setenv disk-led-assoc 0 x y
   
0 is associated with the onboard scsi controller which controls the first four slots : c0t0d0s0   c0t1d0s0   c0t2d0s0   c0t3d0s0
x is an integer between 1 and 10 identifying the rear panel PCI slot number where the lower UltraSCSI controller is installed 
y is an integer between 1 and 10 identifying the rear panel PCI slot
number where the upper UltraSCSI controller is installed
For example:
pci card in slot 5 is connected to lower scsi backplane
pci card in slot 7 is connected to upper scsi backplane
enter the following:
 ok setenv disk-led-assoc 0 5 7
4.  Enter a reset command at the ok prompt
5.  When the system banner is displayed on the monitor, immediately enter 
 the Stop-a sequence on the Sun keyboard.
6.  Enter the following command to perform a reconfiguration boot:
 OK boot -r
This command rebuilds the device trees for the system, incorporating any 
newly installed options. After a device has been added to a device tree,
it can be recognized by the system. After the reconfiguration reboot has 
successfully completed, the system prompt is displayed.
NOTE:
Now that the device tree is build up properly setting the
variable disk-led-assoc with the correct values, prtdiag will
display all the disks that are physically installed in the E450.
#prtdiag -v:
                OK = GREEN              ERROR = YELLOW
                DISK 18:    [OK]        DISK 19:    [OK]
                DISK 16:    [OK]        DISK 17:    [OK]
                DISK 14:    [OK]        DISK 15:    [OK]
                DISK 12:    [OK]        DISK 13:    [OK]
                DISK 10:    [OK]        DISK 11:    [OK]
                 DISK  8:    [OK]         DISK  9:    [OK]
                 DISK  6:    [OK]         DISK  7:    [OK]
                 DISK  4:    [OK]         DISK  5:    [OK]
                 DISK  2:    [OK]         DISK  3:    [OK]
                 DISK  0:    [OK]         DISK  1:    [OK]
NOTE:
all  even  targets are physically installed on the left side of the
bay and all  odd  numbers on the right side.
-----------------------------------------------------------------------
Mapping From Error Message to Disk Slot Number and UNIX Logical Name
     How to translate a UNIX physical device name provided in a SCSI error 
     message to a UNIX logical device name and a disk slot number.
     1.  Determine the UNIX physical device name from the SCSI error message.
         SCSI error messages are typically displayed in the system console
         and logged in the /usr/adm/messages file.
         WARNING: /pci@6,4000/scsi@4,1/sd@3,0 (sd228)
         Error for Command: read(10)     Error level: Retryable
         Requested Block: 3991014        Error Block: 3991269
         Vendor: FUJITSU                 Serial Number: 9606005441
         Sense Key: Media Error
         ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0x0
     In the example SCSI error message above, the UNIX physical device name
     is /pci@6,4000/scsi@4,1/sd@3.
     2. Determine the UNIX logical device name by listing the contents of
        the /dev/rdsk directory.
        Use the grep command to filter the output for any occurrence of
        the UNIX physical device name determined in Step 1:
        % ls -l /dev/rdsk | grep /pci@6,4000/scsi@4,1/sd@3
        lrwxrwxrwx   1 root     root        45 Jan 30 09:07 c12t3d0s0 ->
        ../../devices/pci@6,4000/scsi@4,1/sd@3,0:a,raw
        lrwxrwxrwx   1 root     root        45 Jan 30 09:07 c12t3d0s1 ->
        ../../devices/pci@6,4000/scsi@4,1/sd@3,0:b,raw
        lrwxrwxrwx   1 root     root        45 Jan 30 09:07 c12t3d0s2 ->
        ../../devices/pci@6,4000/scsi@4,1/sd@3,0:c,raw
        lrwxrwxrwx1 root     root        45 Jan 30 09:07 c12t3d0s3 ->
        ../../devices/pci@6,4000/scsi@4,1/sd@3,0:d,raw
        lrwxrwxrwx   1 root     root        45 Jan 30 09:07 c12t3d0s4 ->
        ../../devices/pci@6,4000/scsi@4,1/sd@3,0:e,raw
        lrwxrwxrwx   1 root     root        45 Jan 30 09:07 c12t3d0s5 ->
        ../../devices/pci@6,4000/scsi@4,1/sd@3,0:f,raw
        lrwxrwxrwx   1 root     root        45 Jan 30 09:07 c12t3d0s6 ->
        ../../devices/pci@6,4000/scsi@4,1/sd@3,0:g,raw
        lrwxrwxrwx   1 root     root        45 Jan 30 09:07 c12t3d0s7 ->
        ../../devices/pci@6,4000/scsi@4,1/sd@3,0:h,raw
     The resulting output indicates the associated UNIX logical device name.
     In this example, the logical device name is c12t3d0.
     3. Determine the disk slot number using the prtconf command.
        Substitute the string disk@ for sd@ in the physical device name
       determined in Step 1. The result in this example is
        /pci@6,4000/scsi@4,1/disk@3.
        Use the grep command to find this name in the output of the
        prtconf command:
        % prtconf -vp | grep /pci@6,4000/scsi@4,1/disk@3
          slot#11:  '/pci@6,4000/scsi@4,1/disk@3'                  
   NOTE! When using the "format" command you will need to type "/sd@3,0" in place 
         of "/disk@3".
     
         # format /pci@6,4000/scsi@4,1/sd@3,0
     The resulting output indicates the corresponding disk slot number. In
     this example, the disk slot number is 11.
     If the output does not provide a slot number, the device is either a
     removable media device (CD-ROM or tape drive), an external device
     or the disk-led-assoc openboot PROM parameter is not set correctly.
     
------------------------------------------------------------------------
From: Platform Notes: Sun Ultra 450 Workstation and Ultra Enterprise
450 Server                  
ProductUltra 450 Workstation
Sun Enterprise 450 Server
 Internal Comments
 Audited/updated 11/19/09 - Ian.Macdonald@Sun.COM, Entry Level SPARC Content Team Member
 mapping, names, Ultra 450 Workstation, Sun Enterprise 450 Server
 Previously Published As
 16735
 Change History
 Date: 2008-01-08
 User Name: 95826
 Action: Update Canceled
 Comment: *** Restored Published Content *** canceling update to allow migration to IBIS
 Version: 0
 Date: 2008-01-08
 User Name: 95826
 Action: Reassign
 Comment: reassigning document to release it in order to allow migration to IBIS
 Version: 0
 Date: 2004-05-20
 User Name: 112248
 Action: Rejected
 Comment: Can you mention that the picture is an example of configuration and that the controllers might not be postioned in the same slots. 
 Is there a better picture as this appears a bit blurred.
Attachments
This solution has no attachment