Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1006720.1
Update Date:2009-04-26
Keywords:

Solution Type  Technical Instruction Sure

Solution  1006720.1 :   Single failed hard drive in a Sun StorEdge[TM] T3 array  


Related Items
  • Sun Storage T3 Array
  •  
  • Sun Storage T3+ Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
209363


Description
In order to provide you the most accurate fix, please validate that each statement under the symptoms below is true for your environment. These symptoms will hyperlink you into a relevant content that will 1) tell you how to validate the listed symptom and 2) how to fix the symptom if it is true for your environment. The listed symptoms are ordered in the most appropriate sequence to isolate the issue and be certain about the related fix. Please do not skip a step.
Symptoms:

- failed drive

- degraded LUN

- ASC/ASCQ syslog messages

Environmental Considerations:

- This document assumes that a single drive failure has been validated.



Steps to Follow
Troubleshooting Steps:

NOTE: This is a sub-set of Troubleshooting <Document: 1009745.1> : "Troubleshooting Sun StorEdge[TM] T3 Disk Failures."  The steps below will help you in the replacement of a T3 disk and verifying the replacement was successful.  If the drive has failed more than once, please recheck the syslog and fru stat output.

1. Initiate Disk replacement.

Note: Retain the failed disk until after volume sync is completed after disk replacement.  The volumes sync can be monitored with "proc list."  This can take some time.

2. Verify the state of  the drive replacement by using the 'vol stat' command. The  volume and drive status in a mounted state confirms the drive replacement was successful. It may take a while for the drive replacement to complete as it copies data back to the replaced drive.

     Example:

     storage-t3b:/:<22>vol stat
v1: mounted
u1d05: mounted
u1d06: mounted
u1d07: mounted
u1d08: mounted
Standby: u1d09: mounted
v3: mounted
u2d05: mounted
u2d06: mounted
u2d07: mounted
u2d08: mounted
Standby: u2d09: mounted

3. If  the disk replacement fails for the first time repeat the steps in Troubleshooting <Document: 1009745.1>  : "Troubleshooting Sun StorEdge[TM] T3 Disk Failures."



Product
Sun StorageTek T3+ Array
Sun StorageTek T3 Array

Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains.

To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

storage-os-disk-mid-domain@sun.com


The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK

Place Sun Internal-Use Only content here. This content will be
published to internal SunSolve[SM] only.


T3, T3+, disk, single drive, fault, failed, audited
Previously Published As
86535

Change History
Date: 2007-07-16
User Name: 7058
Action: Approved
Comment: Notes for Normalizaton:
Subset of:86534
Subset Root path:
86535-->86534
References: N/A
Project: Minnow Normalization
Version: 8
Date: 2007-06-27
User Name: 71396
Action: Reassign
Comment: Minnow Flow
Version: 0
Date: 2007-06-27
User Name: 71396
Action: Accept
Comment:
Version: 0



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.