Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1008205.1 : Sun StorageTek[TM] 5000 Series NAS: How to verify LUN Status on NAS
PreviouslyPublishedAs 211265 Description Description Symptoms:
Purpose/scope: This document outlines the procedures that may be used to verify the online status of LUNs in Sun StorEdge[TM] 5210 NAS Appliance (SE5210), Sun StorEdge[TM] 5310 NAS Appliance (SE5310) and Sun StorageTek[TM] 5320 NAS appliance (SE5320). Steps to Follow Verifying LUN Status on NAS 1.The LUN status can be checked using the Web Admin GUI: RAID -> Manage RAID - Check 'Status' is 'Online' for all LUN/Drive(s) 2. For the SE5310 and SE5320 running NAS OS 4.20 or higher, the 'lsi_menu' CLI module can be used to collect directly-attached (CSM1 or CSM2) Disk Array status information. For Gateway-attached arrays, use the associated management interface/GUI to determine the state of the 'gateway' LUN/disks. Connect to the NAS: $ telnet <IP-ADDRESS of NAS> Trying 123.456.123.456... Connected to 123.456.123.456. Escape character is '^]'. connect to (? for list) ? [menu] admin NAS > version StorageTek Model 5320 NAS S/N ST5320C2006356265 Version 4.20 M2 (Build 3) Use the 'load lsi_menu' command to load the module: NAS > load lsi_menu Use the 'lsi_menu' command to enter the utility: NAS > lsi_menu Found 1 Array ************************************************* * SUN Microsystems * * Engenio Raid Utility * * Version 1.0 * ************************************************* 1. Array Menu 2. VolumeGroup Menu 3. Volume Menu 4. Disk Drive Menu 5. Support Menu 6. Exit Select Option 2 to enter the Volume Group menu: Selection: [1 - 6] 2 ***** Volume Group Menu ***** 1. Show All Volume Group 2. Place Volume Group Offline 3. Place Volume Group Online 4. Exit Select Option 1 to show the Volume Group status information: Selection: [1 - 4] 1 Array Number: 1 Number of VolumeGroup(s): 4 VOLUME TRAY LOSS ASSOCIATED DRIVES GRPNO STATUS RAID PROTECT TRAY/SLOT ************************** ARRAY 1 **************************** 2 ONLINE 5 No 85/15,85/14,85/13,85/12,85/11,85/10,85/9 ,85/16 1 ONLINE 5 No 85/7 ,85/6 ,85/5 ,85/4 ,85/3 ,85/2 ,85/1 8 ONLINE 5 No 1/15, 1/14, 1/13, 1/12, 1/11, 1/10, 1/9 , 1/16 7 ONLINE 5 No 1/7 , 1/6 , 1/5 , 1/4 , 1/3 , 1/2 , 1/1 *************************************************************** Note, all Volume Groups are ONLINE (above). The Volume Groups are built from disks in the underlying CSM1 or CSM2 arrays. Select Option 4 to return to the Main menu. Select Option 3 to enter the Volume menu: Selection: [1 - 6] 3 ******* Volume Menu ******* 1. Show Non-Optimal Volumes 2. Show All Volumes (short) 3. Show All Volumes (long) 4. Show one Volume 5. Modify Volume Cache Setting 6. Modify Volume Media Scan Setting 7. Exit NOTE: NAS version 4.21 (lsi_menu release 1.2) has an additional 'Show LUN Mapping' option ******* Volume Menu ******* 1. Show Non-Optimal Volumes 2. Show All Volumes (short) 3. Show All Volumes (long) 4. Show one Volume 5. Show Lun Mapping **** 6. Modify Volume Cache Setting 7. Modify Volume Media Scan Setting 8. Exit Select Option 2 to show the Volume status information: Selection: [1 - 7] 2 Array Number: 1 Number of standard volumes: 7 ----------------CACHE-------------- VOLUME VOL --LUN-- --READ- -WRITE- READ WRITE NAME STAT GB RAID GRP ID SSID ENA ACT ENA ACT MIR CWOB MULT FLSH -----------------ARRAY 1---------------------------------------------------------- 151321_4_Dec_2006 OPT 1 5 2 2 2 1 1 1 1 1 0 1 8 130950_1_Dec_2006 OPT 976 5 2 3 3 1 1 1 1 1 0 1 8 130402_1_Dec_2006 OPT 836 5 1 0 0 1 1 1 1 1 0 1 8 130646_1_Dec_2006 OPT 836 5 1 1 1 1 1 1 1 1 0 1 8 VOL15 OPT 976 5 8 6 14 1 1 1 1 1 0 1 8 VOL16 OPT 976 5 8 7 15 1 1 1 1 1 0 1 8 VOL14 OPT 836 5 7 5 13 1 1 1 1 1 0 1 8 ---------------------------------------------------------------------------------- Note, the status (STAT, column 2) of all Volumes is optimal (OPT) (above). Select the 'Exit' Option to return to the Main menu. Select Option 4 to enter the Disk menu: Selection: [1 - 6] 4 **** Disk Menu **** 1. Show Non-Optimal Drives 2. Show All Drives (short) 3. Show All Drives (long) 4. Show 1 Drive 5. Fail Drive 6. Revive Drive 7. Initialize Drive 8. Exit Select Option 2 to show the Disk Drive status information: Selection: [1 - 8] 2 Array Number: 1 Number of drives: 32 Supported drive types: Fiber (32) TRAYID, CAPACITY CURRENT PRODUCT FIRMWARE SLOT PFA STATUS GB DATARATE ID REV --------------------------- ARRAY 1 ------------------------------- 85,15 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85,14 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85,13 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85,12 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85,11 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85,10 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85, 9 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85, 8 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85, 7 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85, 6 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85, 5 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85, 4 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85, 3 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85, 2 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85, 1 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1,15 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1,14 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1,13 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1,12 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1,11 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1,10 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1, 9 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1, 8 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1, 7 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1, 6 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1, 5 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1, 4 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1, 3 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1, 2 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1, 1 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 85,16 0 Optimal 278 2 Gbps ST330000FSUN300G 055A 1,16 0 Optimal 278 2 Gbps ST330000FSUN300G 055A Note, the status of all Drives is Optimal (above). Select Option 8 to return to the Main menu. Select Option 6 to Exit the utility. Product Sun StorageTek 5320 NAS Gateway/Cluster System Sun StorageTek 5310 NAS Gateway/Cluster System Sun StorageTek 5310 NAS Gateway System Sun StorageTek 5320 NAS Appliance Sun StorageTek 5310 NAS Appliance Sun StorageTek 5210 NAS Appliance Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: storage-nas-domain@sun.com The Knowledge Work Queue for this article is KNO-STO-NAS NAS, 5210, 5310, 5320, LUN, offline, online, normalized Previously Published As 88883 Change History Date: 2010-01-13 User Name: Will Harper Action: Currency check Comment: Re-worded title for findability Date: 2007-06-19 User Name: 97961 Action: Approved Comment: - Applied trademarking where it is missing - Made simple sentence/grammatical corrections Version: 4 Date: 2007-06-19 User Name: 97961 Attachments This solution has no attachment |
||||||||||||
|