Solution Type Technical Instruction Sure Solution 1008402.1 : Sun SPARC Enterprise(R) T5120/5220, Removing/Reinstalling and Replacing the Motherboard [Video]
PreviouslyPublishedAs 211486
Applies to:Sun SPARC Enterprise T5120 ServerSun SPARC Enterprise T5220 Server All Platforms GoalSun SPARC Enterprise(R) T5120/5220, Removing/Reinstalling and Replacing the Motherboard.Video - Motherboard Removal T5120 & T5220 (03:00) Sunsolve users must download the attachment to view the video. SolutionSteps to followIn addition to removing the Motherboard in the event you need to replace it, it must also be removed to access and remove the following FRUs:
Power down the host system (using the front panel power button) or STOP or poweroff command from the SP's root/ILOM or SP's admin/ALOM command line interfaces, respectively. Unplug the system's power cord(s) Implement all the usual anti-static-discharge methods...
Retain the packaging materials from the replacement Motherboard assembly for us in returning the removed motherboard. REMOVING MOTHERBOARD ASSEMBLY 1. Remove the top cover. 2. Remove the air baffle. 3. Remove all PCIe/XAUI riser assemblies. Note: Take note of the location of
expansion cards in PCIe/XAUI risers 0 and 1. 4. Disconnect the motherboard to power
distribution board ribbon cable. 5. Disconnect the hard drive data
cables. 6. Push the plug into the connector. 7. Press the release button. 8. Remove the plug from the connector on the hard drive backplane. Caution: The hard drive data cables are delicate. Ensure they are safely out of the way when servicing the motherboard. 9. If you are replacing the
motherboard, remove the following components: Caution: Some components on the motherboard might be hot. Use caution when handling the motherboard, especially near the CPU heatsink.
Take note of the memory configuration
so that you can install the FBDIMMs in the replacement motherboard.
It is recommended that you put each of the the FBDIMMs in the same
locations they were in the removed motherboard. 10. Using a No.2 Phillips screwdriver, remove the four screws which secure the motherboard assembly to the bus bar. Note: Set the four screws aside. You must use these screws to attach the replacement motherboard to the bus bar during installation. 11. Loosen the captive screw securing the motherboard to the chassis. The captive screw is coloured green, and is located to the left of the bus bar screws. 12. Using the green handle, slide the motherboard back and tilt the motherboard assembly to lift it out of the chassis. Grab the handle and move the
motherboard toward the back of the system and lift it out of the
chassis. 13. Place the motherboard assembly on antistatic mat. Finally, put the removed motherboard assembly in the packing materials provided with the replacement motherboard. INSTALLING THE MOTHERBOARD ASSEMBLY 1. Tilt the motherboard assembly to
position it into the chassis. When you install the motherboard ensure
that you position the board as far forward in the chassis as
possible. 2. Position the motherboard so that its
screw holes align with he chassis stand-offs. 3. Using the green handle and the back
edge of the motherboard tray, push down firmly and equally while
sliding the motherboard to the front of the chassis. Tip: After installing the motherboard
into the chassis, ensure that the motherboard is correctly seated by
gently lifting upon the handles. If the board moves upward,then it is
not correctly seated. Ensure that the motherboard trays is flush with
the chassis floor. Also, check for binds and ensure that the bus bar
screw wholes are correctly aligned with the bus bar at the front of
the motherboard. 4. Tighten the captive screw that
secures the motherboard to the front of its tray in the chassis. 5. Install the four #2 Phillips screws
that secure the motherboard to the bus bar. The four screws that
secure the motherboard to the bus bar are black in colour. Note: When you reinstall the
motherboard, or install a replacement motherboard, you must use the
correct screws to attach the motherboard to the bus bar. 6. If you are installing a replacement motherboard, install the following FRUs:
Note: Only install the FBDIMMs in the slots (connectors) from which they were removed. It is recommended that you put each of the the FBDIMMs in the same locations they were in the removed motherboard. 7. Connect the hard drive data cables. 8. Install the air baffle. 9. Reinstall the motherboard to power
distribution board ribbon cable. 10. Reinstall the PCIe and XUAI risers. 11. Replace the system's top cover. 12. Plug in the system's power
cord(s). If the system administrator would like the Host powered-up, that can be done using the front panel power button, or START or poweron command from the SP's root/ILOM or SP's admin/ALOM command line interfaces, respectively. Product Sun SPARC Enterprise T5220 Server Sun SPARC Enterprise T5120 Server T5120, T5220, motherboard, VT Previously Published As 91523 Change History Date: 2007-12-14 User Name: 71396 Action: Approved Comment: Publishing Version: 1 Date: 2007-12-14 User Name: 71396 Action: Created Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|