Solution Type Technical Instruction Sure Solution 1008484.1 : Validating Modification of Profiles on a StorEdge[TM] 6920
PreviouslyPublishedAs 211597 Description The purpose of this document is to provide basic steps for profile modification for the 6920 array, via the Browser User Interface(BUI) or sscs Command Line Interface(CLI). Content will be limited to a basic usage using the CLI or BUI interface for creating profiles, and provide help with some usage failure scenarios
Steps to Follow Validating Modification of Profiles on a StorEdge[TM] 6920 A. Validate that the profile is not a factory profile Verify the type of profile. If it is listed as a Type of Factory, it cannot be modified from the system. Reference document < Solution: 211582 > Validating Profile State and Status on a StorEdge 6920 (TM) If the type of the profile is not Factory, continue to Step B. B. Validate that the profile is not In Use Verify the status of the profile. Reference document < Solution: 211582 > Validating Profile State and Status on a StorEdge 6920 (TM) If the Status shows In Use, then there is at least one Storage Pool Reference document <Document: 1009823.1> Validating StorEdge(TM) 6920 Pool Deletion If the Profile Status is Not In Use, continue Step C. C. Profile Modification Note: You cannot modify the default factory profiles. If a user-created profile's state is In Use, you can change only the profile name and description. A profile is in the In Use state when it is associated with a storage pool. BUI
SSCS You can modify any field of the profile with a single command. The option The difference is simply to substitute the create command option with the Usage: sscs modify -r <RAID> -v <virt_strategy> -t <array_type> -s <segment> -p <stripe> -N <new_Name> -d <description> -D <hotspare> -k <disk_type> -h <read_ahead> -n <num_drives> profile <profile_name> Example: sscs modify -r 5 -N raid5profile profile raid1profile This command will change the RAID level of the profile to RAID 1, and the name of the profile from raid1profile to raid5profile. D. Verify the Change in the Profile Reference document <Document: 1007159.1> Validating Profile State and Details for Sun StorEdge[TM] 6920 E. Deletion Failure
BUI
Action: Message: Action: Message: Action: Message: Action: If a message appears that is not listed or if the resolution provided does not F. Data Collection
and contact Sun Support Product Sun StorageTek 6920 System Sun StorageTek 6920 Maintenance Update 2 Sun StorageTek 6920 Maintenance Update 1 Internal Comments Validating Modification: This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: storage-os-disk-mid-domain@sun.com The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK.
If the customer reports:
OR
Validate the services on the Service Processor. Reference document <Document: 1007129.1>
Reference document <Document: 1005447.1> Sun StorEdge[TM] 6920 Health Checklist
Provide the following:
And escalate to your next level of support. 6920, profiles, profile, modify, change, how to, normalized, audited Previously Published As 90634 Change History Date: 2007-09-28 User Name: 7058 Action: Approved Comment: OK to publish. Version: 4 Date: 2007-09-28 User Name: 7058 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|