Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1011349.1
Update Date:2010-10-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1011349.1 :   Validating Initiator State and Details for a Sun StorEdge[TM] 6920  


Related Items
  • Sun Storage 6920 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
215568


Description
This document provides the basic steps to review volume state, configuration, and settings information using the Browser or SSCS user interfaces. Use this document if:
  • Initiators are not listed in the UI
  • Initiators are missing information
  • Syntax/Usage is needed to get Initiator state/details

If you are looking for basic administrative tasks on the 6920, please reference



Steps to Follow
Validating Initiator State and Details for a Sun StorEdge[TM] 6920:

A. Validate Initiator Summary

The basic usage for listing a summary of initiators is as follows:

SSCS

sscs list -S storage_domain initiator

This will display:
* Initiator Name
* Storage Domain
* WWN of the initiator
* Status(online/offline)

Note that only initiators that are part of the storage domain specified will be listed. If no domain option is specified, the domain DEFAULT is assumed.

BUI

  1. Click on Configuration Services or Common Array Manager link
  2. Click on Physical Storage tab or menu tree.
  3. Click on Initiators tab

This will display:
* Initiator Name
* OS Type(Standard, HPUX, or Microsoft Windows/Emulex)
* Storage Domain
* State (allocated or free)
* Status (online or offline)
* WWN of the Initiator

A State of Free indicates that there are no volumes mapped to this initiator. A state of Allocated indicates that there are/were volumes
mapped to this initiator.

A Status of online indicates that the 6920 can see this Initiator, on at least one port. Offline indicates that the 6920 cannot see this Initiator, on any port.

B. Validate Initiator Details

SSCS

sscs list initiator <initiator_name>

This will list:
* Initiator Name
* Initiator Description
* Storage Domain
* Initiator WWN
* OS Type
* State
* Status
* Associations(volume associations/mappings)

BUI
# Click on Configuration Services or Common Array Manager link
# Click on Physical Storage tab or menu tree.
# Click on Initiators tab
# Click on Initiator Name link

This will display:
* Initiator Name
* Initiator Description
* Storage Domain
* Initiator WWN
* OS Type
* State
* Status
* Under the Additional Details table you will see a Mapped Volumes link that shows the number of volumes mapped to this initiator, and links you to a summary list of them.

Consider the following actions

  • If you are missing information in the detailed information go to Step D.
  • If an initiator listed has a State of Allocated and a Status of Offline go to Step C.
  • If the Volume details are correct, you have validated the Initiator Details, return to Step 2 of <Document: 1009915.1> Troubleshooting Sun StorEdge[TM] 6920 Configuration Problems

C. Data Collection for Missing or Incorrect Initiators

Please collect the following information:

  • 6920 Solution Extract, reference document <Document: 1003756.1> How to collect an extractor from a Sun StorEdge[TM] 6920 (2.x and 3.x)
  • sscs list initiator <initiator> output show detail(or lack)
  • sscs list sdomain
  • Solaris explorer, reference document <Document: 1006990.1> Sun[TM] Explorer Implementation Best Practice

and contact Sun Support



Product
Sun StorageTek 6920 Maintenance Update 2
Sun StorageTek 6920 Maintenance Update 1
Sun StorageTek 6920 System

Internal Comments
Sun Support

This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

storage-os-disk-mid-domain@sun.com

The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK.


D. Validate that services are running properly on the SP


Reference document <Document: 1007129.1> Validating Services on a Sun StorEdge 6920 Service Processor



E. Perform health check of array


Reference document <Document: 1005447.1> Sun StorEdge[TM] 6920 Health Checklist



F. Escalate


Provide the following:



  • Description of what is not being displayed properly

  • Whether initiators are displayed as Allocated/Offline

  • Results of Step E.

  • Results of Step F.

  • Location of everything in Step C


normalized, list, display, details, initiator, 6920, audited
Previously Published As
90442

Change History
Date: 2007-09-27
User Name: 7058
Action: Approved
Comment: OK to publish.
Spell ck OK.
Tmarks in place, links OK .
No further edits.
Version: 3
Date: 2007-09-21
User Name: 7058
Action: Accept
Comment:
Version: 0
Date: 2007-09-21
User Name: 39181
Action: Approved
Comment: Technical content looks good. Sending for final review.
Version: 0
Date: 2007-09-19
User Name: 88109
Action: Approved
Comment: please review pending 89105
Version: 0
Date: 2007-09-11
User Name: 88109
Action: Created
Comment:
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.