Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1011578.1
Update Date:2010-01-07
Keywords:

Solution Type  Technical Instruction Sure

Solution  1011578.1 :   Sun SPARC(R) Systems that have interlock switch feature.  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire V240 Server
  •  
  • Sun Fire V250 Server
  •  
  • Sun Fire V440 Server
  •  
  • Sun Fire V480 Server
  •  
  • Sun Enterprise 450 Server
  •  
  • Sun Fire 280R Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire V890 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Enterprise 220R Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Enterprise 250 Server
  •  
  • Sun Fire V490 Server
  •  
  • Sun Fire 4810 Server
  •  
  • Sun Enterprise 420R Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
215887


Description
Description

Symptoms:

  • system will not power on

Purpose/Scope:

This document will help the user to identify which systems have an interlock switch which may prevent a system from powering up and those systems that require a physical key as opposed to a virtual keyswitch.



Steps to Follow
Keys:

PRODUCT

AC POWER KEY

POWER INTERLOCK KEY

DOOR KEY

SS1000/SC2000

330-1651

No Interlock

No Key

E150/i 150/nfs 150

No Key

No Interlock

250-1328

U450/UE450/E450

250-1317

No Key 1

250-1317

E250

250-1317

No Key 2

250-1317

E220R/E420R/280R

250-1317

No Interlock

250-1317

E3000/E3500

330-2014

No Interlock

330-2014

E4x00/E5x00/E6x00

330-2014

No Interlock

No Key

Sun Fire V480/V880/V490/V890

330-2014

No Interlock

330-2014

Sun Fire 3800/48x0/6800

330-2014

No Interlock

330-2014

Sun Fire E4900/E6900

330-2014

No Interlock

330-2014

Sun Blade 1000/2000

No Key

No Key 3

None

Sun Fire V240

240-4429

No Interlock

No Key

Sun Fire V250

No Key

No Interlock

240-4341

Sun Fire V440

250-4429

No Interlock

240-4341

Sun Fire V60x/V65x

No Key

No Key 4

No Key

StorEdge A1000/D1000/A5000

No Key

No Interlock

240-2690

StorEdge MultiPack

No Key

No Interlock

330-1966

StorEdge 3120/3310/3510/3511

No Key

No Interlock

No Part#

StorEdge 9900

No Key

No Interlock

6mm Hex

StorEdge L7

No Key

No Interlock

No Part#

StorEdge L20/L40/L60

No Key

No Interlock

No Part#

StorEdge L180

No Key

No Interlock

No Part#

StorEdge L400

No Key

330-1651

No Key

StorEdge L500

No Key

No Part#

No Part#

StorEdge L1000

No Key

330-1651

No Key

StorEdge L11000

No Key

330-1651 5 6

330-1651

A3500

No Part#

No Interlock

No Part#

56" and 68" Rack

330-2014

No Interlock

No Key

72" Expansion Rack

No Part#

No Interlock

No Part# 7

Sun Fire Cabinet

330-2014

No Interlock

330-2014

Sun Rack 900/1000

No Key

No Interlock

240-4254

  1. Removal of the Ultra Enterprise 450 left or right side cover enables an Interlock switch and turns off DC power.

  2. Removal of the Enterprise 250 left side cover or RMA Tray enables an Interlock switch and turns off DC power.

  3. Removal of the SB1000/2000 left cover enables an Interlock switch and turns Off DC power.

  4. Removal of the V60x or V65x top cover enables an Interlock switch and turns Off DC power.

  5. The rear doors of the L11000 have magnetic switches that notify the robotics controller when a door is open. The L11000 will continue to operate with the rear doors open. The doors must be closed for proper cooling.

  6. The L11000 front door interlock switches disable power to the motors when the doors are opened. Override the interlock switches with tool 6311754 and close the low velocity switches to operate the L11000 in low velocity mode with the front doors open.

  7. The front and rear keys are different. Neither key has a Sun part number.

       



Product
Sun Fire V890 Server
Sun Fire V880 Server
Sun Fire V490 Server
Sun Fire V480 Server
Sun Fire V440 Server
Sun Fire V250 Server
Sun Fire V240 Server
Sun Fire 280R Server
Sun Enterprise 450 Server
Sun Enterprise 420R Server
Sun Enterprise 250 Server
Sun Enterprise 220R Server
Sun Fire E6900 Server
Sun Fire E4900 Server
Sun Fire 6800 Server
Sun Fire 4810 Server
Sun Fire 4800 Server
Sun Fire 3800 Server

Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

Domain Lead: Dencho.Kojucharov@sun.com
Feedback Alias: VSP-SPARC-Normalization@sun.com

normalized, interlock, AC power key
Previously Published As
91405

Change History
Date: 2009-11-25
User Name: Anthony Rulli
Action: updated
Comment: currency check, audited by Anthony Rulli, Entry Level SPARC Content team

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback