Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1012024.1
Update Date:2011-05-13
Keywords:

Solution Type  Technical Instruction Sure

Solution  1012024.1 :   How To Resolve Sun StorEdge[TM] 351x Array: SES or PLD Firmware Mismatches  


Related Items
  • Sun Storage 3511 SATA Array
  •  
  • Sun Storage 3510 FC Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
216477


Applies to:

Sun Storage 3511 SATA Array - Version: Not Applicable and later    [Release: N/A and later]
Sun Storage 3510 FC Array - Version: Not Applicable and later    [Release: N/A and later]
All Platforms

Goal

This document illustrates what to look for if you receive the following message indicating a SES or PLD firmware mismatch.
sccli> show ses
Ch Id Chassis Vendor Product ID Rev PLD WWPN
-----------------------------------------------------------------------
2 124 SUN StorEdge 3510F A 1040 A000 204000C0FF000008
3 124 SUN StorEdge 3510F A 1040 8B00* 204000C0FF000008
* indicates SES or PLD firmware mismatch.

Solution


Resolution

Based on the above output, you will need to upgrade your PLD firmware.
You can get the firmware for your particular array from My Oracle Support (MOS).


For the Sun StorEdge[TM] 3510 FC Array, you will need Patchid: 113723-21 (the latest).

For the Sun StorEdge[TM] 3511 SATA Array, you will need Patchid: 113724-12 (the latest).

Please search for Patch Name or Number specifying the full Patchid (ie: 113723-21), 
under the Patches and Updates tab.


Follow the steps outlined in the patch readme.
Upgrade the Program Logic Device(PLD) firmware, which is responsible for
routing Fibre Channel traffic within the subsystem.
After the PLD firmware upgrade, which could take 5 minutes, log out of the
sccli.

sccli> quit

Then, log in again and run a show ses command, to verify there is no longer a
mis-match.
sccli> show ses
Ch Id Chassis Vendor Product ID Rev PLD WWPN
-----------------------------------------------------------------------
2 124 SUN StorEdge 3510F A 1040 1000 204000C0FF000008
3 124 SUN StorEdge 3510F A 1040 1000 204000C0FF000008

The PLD and SES firmware should be the same for both controllers.



Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

storage-os-disk-low-domain@sun.com

The Knowledge Queue for this article is KNO-STO-VOLUME_DISK.
PLD, SES, SE3510, Minnow, firmware, firmware mismatch, 3510, audited, normalized, 3511, SE3511
Previously Published As
71538

Change History
Date: 2009-12-24
User Name: sue.copeland@sun.com
Comment: Currency & Update
Date: 2007-07-03
User Name: 7058
Comment: OK to publish now.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.