Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1012813.1
Update Date:2009-04-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  1012813.1 :   Verifying Sun StorageTek[TM] NAS Replication Network Configuration  


Related Items
  • Sun Storage 5210 NAS Appliance
  •  
  • Sun Storage 5310 NAS Appliance
  •  
  • Sun Storage 5320 NAS Gateway/Cluster System
  •  
  • Sun Storage 5320 NAS Appliance
  •  
  • Sun Storage 5310 NAS Gateway System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Network Attached Storage
  •  

PreviouslyPublishedAs
217593


Description
A dedicated, fully-functional network connection is required between the NAS File Replication master (source) NAS server and the target (mirror) NAS server.

Any operational issues with the 'mirror network' will directly affect the functioning of the mirror process.
This document provides troubleshooting steps to verify correct operation of the 'mirror network'.



Steps to Follow
Verifying Sun StorageTek[TM] NAS Replication Network Configuration

1. The NIC interface(s) used in replication on both the master (source) and mirror (target) NAS systems must be designated as MIRROR

 SE5310         StorEdge 5310C NAS Server Name & Network Address
Server Name     SE5310                           Gateway   123.45.67.1
Interface       emc1                 emc2
Description     Intel Gigabit Copper Intel Gigabit Copper
IO/IRQ/MEM      3070/9               3071/9
H/W Address     00:0e:0c:12:34:56    00:0e:0c:12:34:57
Pkts In/Out     23315501/6392959     8938730/376515
Errs In/Out/Col 0/0/0                0/0/0
MTU Cfg/Act/Max 1500 /1500/1500      1500 /1500/1500
Transceiver     automatic or preset  automatic or preset
IP Address      123.45.67.89         10.10.0.1
IP Subnet Mask  255.255.255.0        255.255.255.0
IP Broadcast    123.45.67.255        10.10.0.255
IP Alias Info
Role            primary      up      mirror       up
^^^^^^

NOTE: It is strongly recommended that the NICs used for NAS replication be configured on a private network.

2. Check for network connectivity between the master and target NAS systems

- Attempt to contact local 'mirroring' network I/F (ie. mirror interface of master system);

   SE5310 > ping <IP-ADDRESS_of_LOCAL_INTERFACE>

-Attempt to contact remote 'mirroring' network I/F (ie. mirror interface of target system)

   SE5310 > ping <IP-ADDRESS_of_REMOTE_INTERFACE>

If the local ping fails, check for mis-configuration of network settings and/or investigate hardware failure of local NIC.

If the remote ping fails, check interconnect cabling. (Also, perform 'local NIC ping' on the remote (target) system to check remote NIC hardware)

If both of the above commands are successful, the mirror network is functional.

3. Check that NIC speed and Duplex setting is correct and that the link is UP

   SE5310 > em show all
emc1: 100Mb/s FULL-DUPLEX, Link is UP
emc2: 100Mb/s FULL-DUPLEX, Link is UP


Product
Sun StorageTek 5320 NAS Gateway/Cluster System
Sun StorageTek 5310 NAS Gateway/Cluster System
Sun StorageTek 5310 NAS Gateway System
Sun StorageTek 5320 NAS Appliance
Sun StorageTek 5310 NAS Appliance
Sun StorageTek 5210 NAS Appliance

Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

storage-nas-domain@sun.com
The Knowledge Work Queue for this article is KNO-STO-NAS.

Normalized, NAS, Replication, Mirror, 5210, 5310, 5320, audited
Previously Published As
88884

Change History
Date: 2007-09-21
User Name: 95826
Action: Approved
Comment: - verified metadata
- changed review date to 2008-09-21
- checked for TM - 1 added + full product name
- checked audience : contract

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback