Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1015053.1 : SL8500 / HSC - Can the hardware audit of the SL8500 be bypassed?
PreviouslyPublishedAs 222759 Description The SL8500 was designed as a non stop 24x7 Library, and the hardware Audit is a design feature of the SL8500: The Door is designed to stay closed and the Various CAPs and access panels are designed to give the necessary access to the Librarys contents. Whenever the Door is opened and closed, it forces a hardware Audit of the contents of the Library. There is no way to disable it. NOTE: The hardware Audit takes all four LSMs offline for about 20 minutes for a Standard modle and up to 45 mins if it has expansions. The Audit needs LMU access to complete and will cause HSC to not fully initialize until the audit is complete and the LMU is released. Steps to Follow No. the Hardware Audit that occurs whenever the Door is opened cannot be bypassed. Product Sun StorageTek SL8500 Modular Library System Sun StorageTek Host Software Component Software SL8500, Hardware Audit, HSC, Can the hardware audit of the SL8500 be bypassed Previously Published As STKKB50256 Attachments This solution has no attachment |
||||||||||||
|