Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1017613.1
Update Date:2011-01-05
Keywords:

Solution Type  Technical Instruction Sure

Solution  1017613.1 :   Netra[TM] v240 - System Board Replacement  


Related Items
  • Sun Netra 240 (DC) Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>NEBS-Certified Servers
  •  

PreviouslyPublishedAs
228788


Description
Both Netra[TM] V240 and the Sun Fire[TM] V240 both use the same system board assembly.

You must reconfigure the fan assembly's for the Netra version. This document
will explain the differences.

Steps to Follow
Netra V240 requires different fan assembly's to provide cooling. This system has 2 fan assembly's, one for the front and rear of the unit. Due to this difference you must follow the caution shown below.
Caution - The system board ships with CPU heat sinks containing fans. Before installing the replacement system board into the Netra 240 server chassis, you must first remove the fans from the CPU heat sink assemblies.
375-3120    Motherboard w/ 2 ? US IIIi 1.28GHz
375-3178    Motherboard w/ 1 ? US IIIi 1.28GHz
The CPU heat sink fans must be removed to enable connection for the
rear/front fan assembly. The rear fan assembly uses connectors P0F0
for the front fan, and P0F1 for the rear fan in this assembly. Also
for the front fan assembly you use connectors F3 for the left hand
fan and F2 for the right hand fan in this assembly.
Note: If you fail to remove the heat-sink fans from the processors
you will see sensor failures from the I2C buss. Always replace the
heat sinks after removal of the fan's.
Note: Be sure to re-attach fans to heat sinks of the system board
being returned.


Product
Netra 240 Server

Internal Comments
Following the link below for the Netra 240 Server Service Manual:


http://dlc.sun.com/pdf/817-2699-13/817-2699-13.pdf

Link to Wiring Diagram:https://support.us.oracle.com/handbook_internal/Systems/Netra_240/wiring_1.html
Replacement, Netra v240, System Board
Previously Published As
80958

Change History
Date: 2010-12-31
User name: Dencho Kojucharov
Action: Currency check
Comments: audited by Entry-Level SPARC Content Lead updated legacy links in the Internal section

Date: 2005-04-25
User Name: 71396
Action: Approved
Comment: Performed final review of article.

updated trademarking.
Publishing.
Version: 3
Date: 2005-04-20
User Name: 71396
Action: Accept
Comment:
Version: 0
Date: 2005-04-20
User Name: 102144
Action: Approved
Comment: check the dos ok to pub

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.