Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1017900.1 : SL8500 - Addressing Host IP Address Conflict, CLI Error Code 3032
PreviouslyPublishedAs 229147
Applies to:Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later [Release: N/A and later]All Platforms Checked for relevance on 12/17/10. GoalSL8500 Host IP Address ConflictThe SL8500 IP address and Host IP address can be configured with an IP address which conflicts with the SL8500 internal LAN resulting in IPL errors, initialization errors, and Cli Error Number 3032. These errors will potentially prevent some of the library sub-assemblies from coming online to the Library Controller. The Host IP address conflict can occur with the library IP addresses assigned to Port_2B, Port_2A, and Host IP addresses used for HSC and ACSLS. SolutionInformation to address the Host IP Address Conflict:
SL8500 Host IP Address Conflict Restricted Address range is: 10.0.0.0 - 10.0.255.255
Note: The first usable customer IP address is: 10.1.0.0. SL8500 Modular Library System, SL8500 Host IP Address Conflict, SL8500, Host IP Address Conflict, CRCM Attachments This solution has no attachment |
||||||||||||
|