Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1018698.1 : Sun StorEdge[TM] 6320/6920 Service Processor USB flash disk LED is red
PreviouslyPublishedAs 230404 Description This document explains the significance of a steady red LED of the Sun StorEdge [TM] 6320/6920 Service Processor USB flash disk. Steps to Follow The Sun StorEdge[TM] 6320/6920 Service Processor (SP) has a flash disk connected to its USB port. This flash disk is used to save the personality files of the SP, so that they can be restored if the SP has to be replaced or reinstalled. The Sun StorEdge 6920 system Getting Started Guide , Chapter , "Installing the System" and Section, "Installing the USB Flash Disk", mentions: "To verify that the flash disk is installed correctly, look for a steady green LED light located at the top of the disk". The Sun StorEdge 6320 system 1.2 Installation Guide, Appendix F, Installing the USB Flash Disk , mentions: If your flash disk has an LED green light, it displays when the flash disk connects correctly . Though the above is true, the following needs to be understood too. There is a cron job (/opt/SUNWsefbru/bin/fbr) that runs every 5 minutes on the SP of the StorEdge[TM] 6920 and every 2 minutes on the SP of the StorEdge[TM] 6320, which saves the personality information into the flash drive. The script first checks if the flash drive is mounted and if it is not, will mount it. The USB flash disk LED will remain a steady red while the drive is mounted. Hence the SP flash disk LED might turn red immediately after installing and might not be green as mentioned in the Getting Started Guide . In summary, the flash disk LED turning red does not indicate any problem. It only indicates that the USB drive has been mounted. Product Sun StorageTek 6920 System Sun StorageTek 6320 System Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: storage-os-disk-mid-domain@sun.com The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK. USB Flash Disk, LED, red, Sun StorEdge[TM] 6320/6920, mount, installation, audited Previously Published As 82294 Change History Date: 2007-08-21 User Name: 7058 Action: Approved Comment: OK to publish. Added normalized keyword. Version: 5 Date: 2007-08-21 User Name: 88109 Action: Approved Comment: added keyword Version: 0 Date: 2007-08-21 User Name: 88109 Action: Update Started Comment: adding normalized keyword for 6920 normalization Version: 0 Date: 2006-11-07 Attachments This solution has no attachment |
||||||||||||
|