Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1020177.1 : ACSLS - Configuration Utility Fails When the SL500 Base Module CAP is Configured for Storage
PreviouslyPublishedAs 253648
Applies to:Sun StorageTek SL500 Modular Library SystemSun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version: 7.3 and later [Release: 7.0 and later] All Platforms Checked for relevance on 3-Feb-2011. GoalDescriptionThe ACSLS configuration utility will fail with a timeout error if the SL500 base module CAP is configured for use as storage cells. The SL500 base module CAP should always be configured for use as I/O cells to enable Enter and Eject operations. SL500 expansion modules may be configured for use as storage or I/O cells. SolutionSteps to Follow This problem only affects the SL500 base module. 1. Verify that the acsss_config utility fails with these error messages: This step builds a database image of your complete library hardware configuration. Before proceeding, make sure that your library is completely configured, that all subsystems are functional and powered on. Build/Verify library configuration? (y or n): y /export/home/ACSSS/config/in_lib_conf: Time-out awaiting library handler response /export/home/ACSSS/config/in_lib_conf: Cannot get LH data /export/home/ACSSS/config/in_lib_conf: Failed to configure LSMs 2008-11-07 12:36:50 791 N in_tbl_dest.c 1 120 The following tables have been removed: acstable,audittable, captable,celltable,csitable,drivetable,lockidtable, lsmtable,paneltable,pooltable,portable,vactable,scr_distr_table,volumetable, clienttable,ptptable,handtable,lmutable,displaycommand,displayoptions, displayfields,displayoptval,displaysubfields lib_config.sh 1612: Error: Configuration command in_lib_conf failed. Exiting. 2. Verify from the Sun Field Engineer how the CAP of the SL500 base module is configured If the CAP is configured for use as I/O, there could be other problems causing the acsss_config to fail. Refer to Document: 1020074.1 Communications Configuration If the CAP is configured for use as storage, ask the Sun Field Engineer to change the CAP to be used for I/O. This is usually done using the SL500 CLI utility and not through ACSLS. Run the acsss_config utility again after making the CAP attribute change. Internal Comments Activated link to < Document: 1020074.1 > ACSLS Configuration Utility Fails, SL500 Base Module CAP, Configured for Storage Attachments This solution has no attachment |
||||||||||||
|